Horacio Medina de Chazal, Ali Zgheib, Angelo Quagliana, Michael Chetrit, Jean Buithieu, Giuseppe Martucci, Marco Spaziano, Ali Abualsaud, Ole de Baker, Laurence Campens, Pascal Theriault-Lauzier, Jere...
Updated on November 17, 2023
To Michele - “Your image will never be forgotten” Nicolo Piazza
The patient selection and procedural planning for transcatheter structural interventions have been facilitated by the extensive use of multislice computed tomography (MSCT) multiplanar reconstruction. This imaging technique allows the identification of the optimal fluoroscopic viewing angles of left- and right-sided heart structures, in particular the aortic, mitral and tricuspid valve complexes. The use of standardized fluoroscopic viewing angles, during transcatheter interventions, can be extremely helpful in technically challenging scenarios (e.g., bifurcation stenting, aortic, mitral and tricuspid valve interventions). The continuous refinement of transcatheter procedural techniques and the emergence of novel transcatheter devices challenge our understanding and applicability of multimodality imagining. Mastering multimodality imaging of the heart chamber anatomy can reduce the procedural time, radiation dose, contrast volume, and complications during transcatheter coronary and structural interventions while providing guidance for the operators. In this chapter we aim to describe the anatomy of the heart with respect to structural interventions and coronary arteries by integrating MSCT, fluoroscopy and echocardiography. By doing so, we also describe the utility of optimal fluoroscopic viewing angles in guiding structural and coronary interventions.
Traditionally, percutaneous coronary interventions (PCI) are performed using well-recognized anatomical patterns based on familiar fluoroscopic viewing angles. Coronary angiography has indeed an excellent resolution, but its two-dimensional (2D) nature inherently limits its diagnostic accuracy due to foreshortening and overlap of structures . Since the introduction of transcatheter structural heart therapies, cardiologists have become increasingly aware of the importance of understanding anatomical details of cardiac structures under fluoroscopy . Many critical anatomical structures comprise several spatial components arranged in a complex three-dimensional (3D) geometry. Even though these anatomical and functional components have been the topic of numerous publications , little consideration has been given to understanding their configuration as appreciated under fluoroscopy . Understanding fluoroscopic cardiac anatomy can facilitate optimal positioning and deployment of prostheses during transcatheter valve repair/replacement, left atrial appendage occlusion, septal defect closure, paravalvular leak closure. Commonly, these therapies are conducted using standard fluoroscopic angulations irrespective of variations in anatomy. However, it is possible that patient-specific fluoroscopic viewing angles can improve procedural safety and efficacy.
Interestingly, the common chamber views appreciated on echocardiography can be appreciated across imaging modalities, including fluoroscopy, thereby providing the basis for a common language (i.e. imaging modality independent). Furthermore, optimal projection curves (i.e. S-curves) that provide fluoroscopic viewing angles of a structure in-plane or en-face can be interrelated with fluoroscopic chamber views. Understanding the relationship between chamber views and optimal projection curves is the fundamental principle in mastering “fluoroscopic anatomy” .
MSCT multiplanar reconstruction of the aortic valvular complex has enhanced patient selection and procedural planning for transcatheter aortic valve implantation . For example, MSCT affords physicians the opportunity to pre-select optimal x-ray fluoroscopic viewing angles for deployment of the valve prosthesis . Such angle optimization may decrease procedure time, radiation exposure, and injected contrast agent volume . It may reduce the risk of acute kidney injury and paravalvular regurgitation , conduction disturbances or valve embolization. The same principles can be applied for planning of any fluoroscopy-guided procedure, including coronary interventions.
The goal of this chapter is to provide knowledge regarding 1- the fluoroscopic chamber views of the right and left heart 2- the optimal projection curves of the various cardiac structures (i.e. aortic, mitral and tricuspid valves, atrial septum, left atrial appendage, left and right coronary ostia) 3- integration of this knowledge toward transcatheter structural heart interventions and percutaneous coronary interventions.
The use of a particular terminology to describe the heart impacts the way physicians describe the structures of the heart. Distinct anatomical terminologies are used by imagers using different imaging modalities. These dissimilarities are often experienced as a major obstacle during procedural planning and realization. For instance, the mid-esophageal mitral bicommissural view on transeophageal echocardiography, the horizontal long-axis view on nuclear cardiac imaging and the right anterior oblique (RAO)/cranial (CRA) projection on fluoroscopy all depict a two-chamber view of the left heart. In fact, the way the heart appears is a matter of viewing angle rather than imaging modality. A three-chamber view of the left heart, showing the left atrium, left ventricle and left ventricular outflow tract (LVOT)/aorta, can be obtained from an anatomical preparation of the heart as well as by echocardiography, fluoroscopy, MSCT or magnetic resonance imaging as long as the heart is considered from a similar angle (The way the heart appears is a matter of viewing angle rather than imaging modality. Three chamber view of the left heart viewed on (left to right) an anatomical preparation, echocardiography, fluoroscopy, MSCT and MRI.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-1.pptx"})' class="cursor-pointer">Figure 1). The use of a common “anatomy-centric” terminology, rather than “modality-centric” terminology, is thus mandatory to bridge the gaps across imaging techniques. The following principles may pave the way to a common multimodality terminology that will allow for an easier and more efficient interaction between imagers and operators in the catheterization laboratory.
The way the heart appears is a matter of viewing angle rather than imaging modality. Three chamber view of the left heart viewed on (left to right) an anatomical preparation, echocardiography, fluoroscopy, MSCT and MRI.
In our discussion, structures will be termed according to their attitudinally correct anatomical position . This implies that the subject is facing the observer and standing upright. Thus, structures closer to the observer are described as being anterior and those relatively farther away within the body are posterior. Components lying closer to the head are superior (i.e., CRA) and those toward the feet are said to be inferior (i.e., caudal [CAU]). Structures to the left-hand side of the observer are right-sided and those to the observer’s right are left-sided (Attitudinal description of heart anatomy. structures should be termed according to their attitudinally correct anatomical position. structures closer to the observer are described as being anterior and those relatively farther away within the body are posterior. Components lying closer to the head are superior and those toward the feet are said to be inferior. Structures to the left-hand side of the observer are right-sided and those to the observer\u2019s right are left-sided.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-2.pptx"})' class="cursor-pointer">Figure 2).
Attitudinal description of heart anatomy. structures should be termed according to their attitudinally correct anatomical position. structures closer to the observer are described as being anterior and those relatively farther away within the body are posterior. Components lying closer to the head are superior and those toward the feet are said to be inferior. Structures to the left-hand side of the observer are right-sided and those to the observer’s right are left-sided.
The fluoroscopic screen portrays the thorax in an upright orientation despite the patient being in a supine position. Superior and inferior structures are appreciated in the upper and lower halves of the screen. The direction of fluoroscopic projections is described based on 2 conventional angles, CRA/CAU and left anterior oblique (LAO)/RAO (Geometry of the Optimal Projection Curve. The vector joining the x-ray source and the center point of the detector is designated Vd, and the vector pointing along a structure of interest is Vs. (A and B) The angular system (cranial [CRA]\/caudal [CAU] and right anterior oblique [RAO]\/left anterior oblique [LAO] angles) used in fluoroscopy is described. (C) All vectors Vd perpendicular to vector vs are optimal viewing angles. The optimal projection curve is the plot of the fluoroscopic angles of all vectors Vd for a particular structure of interest. (D) A typical S-shaped optimal projection curve for a given cardiac structure is shown.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-3.pptx"})' class="cursor-pointer">Figure 3 A and Geometry of the Optimal Projection Curve. The vector joining the x-ray source and the center point of the detector is designated Vd, and the vector pointing along a structure of interest is Vs. (A and B) The angular system (cranial [CRA]\/caudal [CAU] and right anterior oblique [RAO]\/left anterior oblique [LAO] angles) used in fluoroscopy is described. (C) All vectors Vd perpendicular to vector vs are optimal viewing angles. The optimal projection curve is the plot of the fluoroscopic angles of all vectors Vd for a particular structure of interest. (D) A typical S-shaped optimal projection curve for a given cardiac structure is shown.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-3.pptx"})' class="cursor-pointer">Figure 3 B). In the anteroposterior (AP) viewing angle (CRA/CAU 0, LAO/RAO 0), right- and left-sided structures are found on the left and right sides of the screen, respectively. Of note, discussing heart structures in their attitudinal position is in perfect agreement with nomenclatures used for MSCT, x-ray fluoroscopic imaging and magnetic resonance imaging (Attitudinal viewing of MSCT image simulating the C-arm rotation around a lying patient in the catheterization laboratory. (A) Sagittal view: from an anterior position structure closer to the head are labelled as cranial (CRA) and those closer to the feet are labelled as caudal (CAU). (B) Axial view: from an anterior position structure closer to the right of the patients are labelled as right anterior oblique (RAO) and those closer to the left are labelled as left anterior oblique (LAO).<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-4.pptx"})' class="cursor-pointer">Figure 4); this is not necessarily true with echocardiography.
Geometry of the Optimal Projection Curve. The vector joining the x-ray source and the center point of the detector is designated Vd, and the vector pointing along a structure of interest is Vs. (A and B) The angular system (cranial [CRA]/caudal [CAU] and right anterior oblique [RAO]/left anterior oblique [LAO] angles) used in fluoroscopy is described. (C) All vectors Vd perpendicular to vector vs are optimal viewing angles. The optimal projection curve is the plot of the fluoroscopic angles of all vectors Vd for a particular structure of interest. (D) A typical S-shaped optimal projection curve for a given cardiac structure is shown.
Attitudinal viewing of MSCT image simulating the C-arm rotation around a lying patient in the catheterization laboratory. (A) Sagittal view: from an anterior position structure closer to the head are labelled as cranial (CRA) and those closer to the feet are labelled as caudal (CAU). (B) Axial view: from an anterior position structure closer to the right of the patients are labelled as right anterior oblique (RAO) and those closer to the left are labelled as left anterior oblique (LAO).
Fluoroscopy is used to guide the vast majority of transcatheter cardiac procedures. Inherently, it is a 2D imaging modality that requires the user to select a viewing angle that provides accurate information on device positioning. For a particular structure, an optimal viewing angle should minimize positioning errors due to parallax. The goal of many transcatheter procedures - such as valve implantation, laft atrial appendage occlusion, septal defect closure, and paravalvular leak occlusion - is to implant a quasi-cylindrical device inside a highly variable anatomical structure. The fluoroscopic projection that minimizes parallax during deployment is such that the source-to-detector direction is orthogonal to the axis of symmetry of the anatomical feature of interest (Geometry of the Optimal Projection Curve. The vector joining the x-ray source and the center point of the detector is designated Vd, and the vector pointing along a structure of interest is Vs. (A and B) The angular system (cranial [CRA]\/caudal [CAU] and right anterior oblique [RAO]\/left anterior oblique [LAO] angles) used in fluoroscopy is described. (C) All vectors Vd perpendicular to vector vs are optimal viewing angles. The optimal projection curve is the plot of the fluoroscopic angles of all vectors Vd for a particular structure of interest. (D) A typical S-shaped optimal projection curve for a given cardiac structure is shown.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-3.pptx"})' class="cursor-pointer">Figure 3 C). Based on this criterion, it is possible to determine an optimal CRA/CAU angle for any given LAO/RAO angle. The plot of the optimal combinations is called the optimal projection curve .
In addition to parallax errors, optimal viewing angles should minimize the overlap of anatomic structures, a problem that also stems from the 2D nature of fluoroscopy. In the context of transcatheter interventions, some cardiac structures must be accurately located to correctly implant devices. The overlap of a highly attenuating anatomical structures within the region of implantation may negatively influence the contrast-to-noise ratio and compromise visualization. Therefore, it becomes critical to appreciate the fluoroscopic views that provide maximal separation between structures of interest. This understanding can be obtained from MSCT which depicts cardiac structures with relatively high soft-tissue contrast, as well as high temporal and spatial resolution.
MSCT records a 3D volume dataset of the heart and can accurately determine the attitudinal position of cardiac structures in the body (Geometry of the Optimal Projection Curve. The vector joining the x-ray source and the center point of the detector is designated Vd, and the vector pointing along a structure of interest is Vs. (A and B) The angular system (cranial [CRA]\/caudal [CAU] and right anterior oblique [RAO]\/left anterior oblique [LAO] angles) used in fluoroscopy is described. (C) All vectors Vd perpendicular to vector vs are optimal viewing angles. The optimal projection curve is the plot of the fluoroscopic angles of all vectors Vd for a particular structure of interest. (D) A typical S-shaped optimal projection curve for a given cardiac structure is shown.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-3.pptx"})' class="cursor-pointer">Figure 3 D). Consequently, the MSCT volumetric dataset can help create an optimal projection curve describing the orthogonal orientation of any cardiac structure. Given that fluoroscopy and MSCT share a common image contrast mechanism, i.e., x-ray attenuation, it is possible to use MSCT volumetric data to simulate fluoroscopic images. A ray-casting method based on this principle will be used to generate the fluoroscopic images presented in this chapter to demonstrate how MSCT may provide optimal fluoroscopic viewing angles for heart structures (Integration of multimodality imaging data. Both MSCT and fluoroscopy hinge on the same image contrast mechanism, X-ray attenuation. It is thus possible to apply MSCT volumetric data to simulate fluoroscopic images, using a ray-casting method. This feature permits parallel registration and rotation of MSCT and fluoroscopy images using a virtual C-arm analogous to that used in the catheterization laboratory.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-5.pptx"})' class="cursor-pointer">Figure 5). It is important to note that while fluoroscopic angulations of heart structures are dependent on the general orientation of the heart within the thorax , exact angulations may be determined for a specific patient prior to an intervention. Measurement of fluoroscopic angulation from MSCT data can be done with visualization software packages that offer double-oblique multiplanar reconstruction; the exact CRA/CAU and RAO/LAO angulations for a particular structure can be obtained by analyzing the oblique sagittal and oblique transverse views, respectively.
Integration of multimodality imaging data. Both MSCT and fluoroscopy hinge on the same image contrast mechanism, X-ray attenuation. It is thus possible to apply MSCT volumetric data to simulate fluoroscopic images, using a ray-casting method. This feature permits parallel registration and rotation of MSCT and fluoroscopy images using a virtual C-arm analogous to that used in the catheterization laboratory.
Recognition of heart chamber views is well established in echocardiography. The radiolucency of cardiac structures projected by fluoroscopy has accustomed interventional cardiologists to specific patterns of contrast-enhanced chambers and arteries while overlooking the global 3D cardiac structure. We can translate anatomical information and patterns across imaging modalities using classical echocardiographic chamber views as a foundation. In addition to providing the basis for a common language, “fusing imaging modalities in the mind” through chambers views can take advantage of the temporal/spatial resolution of the various imaging modalities. The way the heart appears is a matter of viewing angle rather than imaging modality. Three chamber view of the left heart viewed on (left to right) an anatomical preparation, echocardiography, fluoroscopy, MSCT and MRI.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-1.pptx"})' class="cursor-pointer">Figure 1 demonstrates a three-chamber view of the heart by echocardiography, fluoroscopy, MSCT and magnetic resonance imaging. Given that the relative orientation of cardiac structures is constant within a given chamber view, knowledge transfer is possible across imaging modalities.
Simulated fluoroscopic chamber views of the right and left heart can be generated from MSCT volumetric data (Fluoroscopic chamber views and corresponding multislice computed tomography imaging of the left- and right heart. Throughout the chapter, chamber views are color-coded: 1-chamber (blue); 2-chamber (yellow); 3-chamber (red); 4-chamber (green), when not stated otherwise. Abbreviations: CAU = caudal; CRA = cranial; LAO = left anterior oblique; MSCT = multislice computed tomography; RH = right heart.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-6.pptx"})' class="cursor-pointer">Figure 6). In summary, the left heart chamber views are as follows: 1-chamber view in LAO CAU, 2-chamber in shallow RAO CRA, 3-chamber in steep RAO CAU, and 4-chamber in LAO/RAO extreme CRA views. The location of the 1- and 4-chamber views of the right heart are similar to those of the left, while the location of the right heart 2- and 3-chamber views are interchanged i.e., 3-chamber in shallow RAO CRA and 2-chamber in steep RAO CAUD. It is for this reason that the echocardiographer can easily transition from a 2-chamber view of the right heart to a 3-chamber view of the left heart by simply angulating the ultrasound beams more posteriorly. “Blending” of chamber views (e.g., hybrid between 1 and 2-chamber views) can occur while transitioning across the fluoroscopic grid. Of note, additional views of the left and right heart such as the short-axis of the aortic valve and bicaval views can be achieved in extreme RAO CRAN and LAO CAU views, respectively.
Fluoroscopic chamber views and corresponding multislice computed tomography imaging of the left- and right heart. Throughout the chapter, chamber views are color-coded: 1-chamber (blue); 2-chamber (yellow); 3-chamber (red); 4-chamber (green), when not stated otherwise. Abbreviations: CAU = caudal; CRA = cranial; LAO = left anterior oblique; MSCT = multislice computed tomography; RH = right heart.
While MSCT can generate 3D cross-sectional images or slabs of variable millimeter thickness, the fluoroscopic image is a 2D summation of cardiac structures depending on the angle of projection. Each left/right fluoroscopic chamber view can be characterized by specific anatomical structures that appear in perpendicular or en-face projections and allows the operator to begin the process of pattern recognition that will be described in the ensuing paragraphs.
The regions of fluoroscopic angulations corresponding to each of the chamber views and the specific structures of interest of the left heart are shown in Fluoroscopic chamber views of the left heart. The region of fluoroscopic angulations corresponding to each of the chamber views of the left heart is shown. The mitral valve, aortic valve and atrial septum are traced in blue, yellow and green respectively. Average coordinates appear in Figure 5. CAU: caudal; CRA: cranial; LAO: left anterior oblique; RAO: right anterior oblique.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-7.pptx"})' class="cursor-pointer">Figure 7 and Fluoroscopic chamber views of the left heart. The region of fluoroscopic angulations corresponding to each of the chamber views of the left heart is shown. The mitral valve, aortic valve and atrial septum are traced in blue, yellow and green respectively. Average coordinates appear in Figure 5. CAU: caudal; CRA: cranial; LAO: left anterior oblique; RAO: right anterior oblique.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-8.pptx"})' class="cursor-pointer">Figure 8, respectively.
Fluoroscopic chamber views of the left heart. The region of fluoroscopic angulations corresponding to each of the chamber views of the left heart is shown. The mitral valve, aortic valve and atrial septum are traced in blue, yellow and green respectively. Average coordinates appear in Figure 5. CAU: caudal; CRA: cranial; LAO: left anterior oblique; RAO: right anterior oblique.
Fluoroscopic chamber views of the left heart. The region of fluoroscopic angulations corresponding to each of the chamber views of the left heart is shown. The mitral valve, aortic valve and atrial septum are traced in blue, yellow and green respectively. Average coordinates appear in Figure 5. CAU: caudal; CRA: cranial; LAO: left anterior oblique; RAO: right anterior oblique.
The main features of multimodality imaging of the left heart are summarized in Multimodality imaging of the left side of the heart, aortic and mitral valve. The optimal projection curves of the aortic and mitral annulus are plotted as a blue dotted line (aortic valve annulus) and green dotted line (mitral valve annulus). The region of fluoroscopic angulations corresponding to each of the chamber views is indicated by circles. The panels correspond to the two-chamber (yellow), three- chamber (red) and the four-chamber (green) views. Each panel presents the matching echocardiographic and MSCT images corresponding to the fluoroscopic view of interest (circles). LAO: left anterior oblique; MSCT: multislice computed tomography; RAO: right anterior oblique; TOE: transoesophageal echocardiography; TTE: transthoracic echocardiography.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-9.pptx"})' class="cursor-pointer">Figure 9 and Fluoroscopic left sided cardiac structures in A (one chamber), B (two chamber), C (three chamber) and D (four chamber) view. The main cardiac structures are highlighted with circles, namely: superior pulmonary veins (green), inferior pulmonary veins (brown), left atrial appendage (orange), inter atrial septum (blue), aortic annulus (yellow), mitral annulus (violet), superior papillary muscle (pink), inferior papillary muscle (red). \u00a0\u00a0<\/span><\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-10.pptx"})' class="cursor-pointer">Figure 10.
Multimodality imaging of the left side of the heart, aortic and mitral valve. The optimal projection curves of the aortic and mitral annulus are plotted as a blue dotted line (aortic valve annulus) and green dotted line (mitral valve annulus). The region of fluoroscopic angulations corresponding to each of the chamber views is indicated by circles. The panels correspond to the two-chamber (yellow), three- chamber (red) and the four-chamber (green) views. Each panel presents the matching echocardiographic and MSCT images corresponding to the fluoroscopic view of interest (circles). LAO: left anterior oblique; MSCT: multislice computed tomography; RAO: right anterior oblique; TOE: transoesophageal echocardiography; TTE: transthoracic echocardiography.
Fluoroscopic left sided cardiac structures in A (one chamber), B (two chamber), C (three chamber) and D (four chamber) view. The main cardiac structures are highlighted with circles, namely: superior pulmonary veins (green), inferior pulmonary veins (brown), left atrial appendage (orange), inter atrial septum (blue), aortic annulus (yellow), mitral annulus (violet), superior papillary muscle (pink), inferior papillary muscle (red).
Short-axis view of the left ventricle can be obtained in a LAO projection with CAU angulation (average fluoroscopic angulation: LAO50°/CAU20°) . It provides a clear separation of the aortic and mitral valves. This projection provides the en-face or short axis view of the left ventricle and mitral valve (major and minor diameter). By displaying the mitral valve en-face, the one-chamber view is useful for the guidance of procedures requiring separation of the anterior and posterior mitral valve leaflets and leaflet scallops. The papillary muscles are also viewed in short-axis and are located in the posterior half of the left ventricle. In the short-axis view, we can appreciate the atrial septum in plane, the major axis of the left atrial appendage ostium, and separation of the superior/inferior and right/left pulmonary vein.
The corresponding views on transthoracic echocardiography can be appreciated from the parasternal and subcostal short axis views and on transoesophageal echocardiography from a transgastric short-axis 0° view. Nowadays, modern matrix probes can perform multiplanar reconstructions and generate the desired chamber views.
The two-chamber view can be obtained with a shallow RAO CRA angulation (average fluoroscopic angulation: RAO30°/CRA15°) . Aortic and mitral valves are overlapped. This view allows to appreciate the major axis of the aortic and mitral valve annuli. The two-chamber view is useful to separate the mitral leaflet scallops with A3/P3, A2/P2, and A1/P1 oriented from left to right on the screen. This view depicts the long axis of the superior and inferior papillary muscles with maximum separation between them, which could facilitate operators in targeting these structures. Furthermore, this view provides the minor axis of the left atrial appendage ostium in plane. Superior and inferior pulmonary veins are overlapping while right and left pulmonary veins are separated.
On transoesophageal echocardiography, the two-chamber view can be appreciated from a mid-esophageal 90° or transgastric long-axis 90° view or using echocardiographic multiplanar reconstructions.
A three-chamber view can be obtained in a steep RAO CAU projection (average fluoroscopic angulation: RAO60°/CAU45°) . This view separates the aortic valve and LVOT from the mitral valve and is useful to evaluate for LVOT obstruction. The minor axis of the aortic and mitral annuli is visualized and can therefore be useful for appreciating balloon expansion or frame compression during transcatheter aortic and mitral valve procedures. The anterior and posterior mitral valve leaflets are separated in a superior/inferior location on the fluoroscopic screen, respectively. The 3-chamber view overlaps both papillary muscles on the inferior aspect of the left ventricle and can be used to avoid them during stiff guidewire or Impella positioning (Usefulness of fluoroscopic 3-chamber view for Impella positioning. The 3-chamber view overlaps both papillary muscles (red and green circles) on the inferior aspect of the left ventricle and can be used to avoid them during stiff guidewire or Impella positioning.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-11.pptx"})' class="cursor-pointer">Figure 11). The three-chamber view also demonstrates an en-face view of the atrial septum and the left atrial appendage ostium and therefore not a recommended chamber view for LAA occlusion. Superior and inferior pulmonary veins as well as right and left pulmonary veins are separated.
Usefulness of fluoroscopic 3-chamber view for Impella positioning. The 3-chamber view overlaps both papillary muscles (red and green circles) on the inferior aspect of the left ventricle and can be used to avoid them during stiff guidewire or Impella positioning.
The fluoroscopic three-chamber fluoroscopic view corresponds to the parasternal long-axis or apical three-chamber view on transthoracic echocardiography. Similar views can be obtained from a mid-esophageal long-axis 120°-140° or transgastric long- axis 110°-130° view.
Four-chamber view can be obtained by placing the fluoroscopic C-arm in an extreme CRA projection with a variable RAO or LAO projection (average fluoroscopic angulation: LAO10°/CRA60°) . The fluoroscopic four-chamber view can provide the mitral valve annulus and atrial septum simultaneously in plane and can be useful for transcatheter mitral valve replacement procedures. This view displays full separation between left- and right-ventricles and atria and sets the ventricular and atrial septa in plane. The aortic and mitral valves are nearly superimposed, the mitral valve leaflets and scallops appear overlapped.
The fluoroscopic 4-chamber view corresponds to the transthoracic apical 4-chamber view or mid-to-low transesophageal view at 0°-20°. Due to the 2-dimensional nature of fluoroscopy, the 4-chamber and 5-chamber views can be said to be “overlapped”.
The regions of fluoroscopic angulations corresponding to each of the chamber views of the right heart are shown in Fluoroscopic chamber views of the right heart. The region of fluoroscopic angulations corresponding to each of the chamber views of the right heart is shown. The tricuspid valve is traced in orange. CAU: caudal; CRA: cranial; LAO: left anterior oblique; RAO: right anterior oblique.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-12.pptx"})' class="cursor-pointer">Figure 12. Co-registration of MSCT and fluoroscopy of right heart structures is shown in Multislice computed tomography chamber views of right-sided heart structures and corresponding fluoroscopy. A. TV=tricuspid valve, in yellow; B. CS=coronary sinus, in blue; C. SVC= superior vena cava, in orange; D. IVC=inferior vena cava, in green; E. AS=atrial septum, in red; F. PV=pulmonary valve, in purple. Structures are determined on MSCT (left column) and the simulated fluoroscopy (right column). RA=right atrium; RV=right ventricle.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-13.pptx"})' class="cursor-pointer">Figure 13.
Fluoroscopic chamber views of the right heart. The region of fluoroscopic angulations corresponding to each of the chamber views of the right heart is shown. The tricuspid valve is traced in orange. CAU: caudal; CRA: cranial; LAO: left anterior oblique; RAO: right anterior oblique.
Multislice computed tomography chamber views of right-sided heart structures and corresponding fluoroscopy. A. TV=tricuspid valve, in yellow; B. CS=coronary sinus, in blue; C. SVC= superior vena cava, in orange; D. IVC=inferior vena cava, in green; E. AS=atrial septum, in red; F. PV=pulmonary valve, in purple. Structures are determined on MSCT (left column) and the simulated fluoroscopy (right column). RA=right atrium; RV=right ventricle.
The main features of multimodality imaging of the right heart are summarized in Multimodality imaging of the right side of the heart and tricuspid valve. Multimodality imaging of the left side of the heart, aortic and mitral valve. The optimal projection curves of the aortic and mitral annulus are plotted as a blue dotted line (aortic valve annulus) and green dotted line (mitral valve annulus). The region of fluoroscopic angulations corresponding to each of the chamber views is indicated by circles. The panels correspond to the two-chamber (yellow), three- chamber (red) and the four-chamber (green) views. Each panel presents the matching echocardiographic and MSCT images corresponding to the fluoroscopic view of interest (circles). LAO: left anterior oblique; MSCT: multislice computed tomography; RAO: right anterior oblique; TOE: transoesophageal echocardiography; TTE: transthoracic echocardiography.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-14.pptx"})' class="cursor-pointer">Figure 14 and Fluoroscopic right sided cardiac structures in A (one chamber), B (two chamber), C (three chamber) and D (four chamber) view. The main cardiac structures are highlighted with circles, namely: tricuspid valve (violet), free edge of the anterior (yellow), septal (white) and posterior (blue) tricuspid valve leaflets, superior papillary muscle (green dot), inferoposterior papillary muscle (violet dot), inferoanterior papillary muscle (red dot), pulmonary valve (blue), inferior vena cava (orange), superior vena cava (turquoise), coronary sinus (red), and interatrial septum (green).\u00a0<\/span><\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-15.pptx"})' class="cursor-pointer">Figure 15.
Multimodality imaging of the right side of the heart and tricuspid valve. Multimodality imaging of the left side of the heart, aortic and mitral valve. The optimal projection curves of the aortic and mitral annulus are plotted as a blue dotted line (aortic valve annulus) and green dotted line (mitral valve annulus). The region of fluoroscopic angulations corresponding to each of the chamber views is indicated by circles. The panels correspond to the two-chamber (yellow), three- chamber (red) and the four-chamber (green) views. Each panel presents the matching echocardiographic and MSCT images corresponding to the fluoroscopic view of interest (circles). LAO: left anterior oblique; MSCT: multislice computed tomography; RAO: right anterior oblique; TOE: transoesophageal echocardiography; TTE: transthoracic echocardiography.
Fluoroscopic right sided cardiac structures in A (one chamber), B (two chamber), C (three chamber) and D (four chamber) view. The main cardiac structures are highlighted with circles, namely: tricuspid valve (violet), free edge of the anterior (yellow), septal (white) and posterior (blue) tricuspid valve leaflets, superior papillary muscle (green dot), inferoposterior papillary muscle (violet dot), inferoanterior papillary muscle (red dot), pulmonary valve (blue), inferior vena cava (orange), superior vena cava (turquoise), coronary sinus (red), and interatrial septum (green).
The one-chamber (short-axis) view of the right heart displays the en-face view of the tricuspid valve and it can be obtained in a LAO CAU angulation (average fluoroscopic angulation: LAO55°/CAU15°) . The one-chamber view of the right heart is critical to understanding the attitudinal orientation of right-sided heart structures given that the superior and inferior vena cava, and atrial septum are simultaneously in plane while the tricuspid valve annulus is in short-axis. It is also useful for targeting the structures of interest by matching the fluoroscopic disposition of the tricuspid leaflets (septal, anterior and posterior) with a modified (upside down) transgastric transesophageal echocardiography view, seen from the ventricular side. In this view,
Bicaval view. MSCT (A), fluoroscopic (B), conventional and modified TEE (C-D) and TEE Live 3D (E-F) bicaval matching views of the right atrium. The modified echocardiographic displays were inverted left/right and rotated 90 clockwise from the classical TEE bicaval view. In this view the superior and inferior venae cavae (turquoise and orange circles, respectively) can be visualized both in plane as well as the inferior vena cava and the interatrial septum (green circle). The fluoroscopic is obtained by angulating the C-arm in a LAO90°/CRA10° projection. Tricuspid valve (violet circle) is “en face” and its anterior (yellow line), posterior (blue line) and septal (white line) leaflets are separated.
The one-chamber view can be obtained using a transesophageal basal transgastric window (0°-20°) or by 3D acquisitions during transthoracic or transesophageal echocardiography.
A two-chamber (right ventricle inflow) view of the right heart can be obtained in a steep RAO CAU projection (average fluoroscopic angulation: RAO60°/CAU50°) . This view can be potentially helpful to identify the attachments of the anterior and posterior leaflets of the tricuspid valve to the atrioventricular junction. Separation of superior papillary muscle from infero-posterior and infero-anterior papillary muscles.
Setting a mild CAU angulation can provide the orifice of the inferior vena cava and the tricuspid valve simultaneously in plane allowing to better understand the precise angle between these two structures and guide delivery catheters from the inferior vena cava across to the tricuspid valve and into the right ventricular inflow tract (RVOT). This view also displays the atrial septum “en-face”.
During attempts to enter the right ventricle, caution is needed to avoid entering and/or injuring the coronary sinus, whose orifice is at 90 degrees with the tricuspid valve annulus. Using a fluoroscopic RAO projection with CAU angulation permits to achieve maximal separation between the coronary sinus and the tricuspid valve, while both structures are in plane (Chamber view anatomy of the Coronary Sinus. (A) MSCT, (B) endovascular, and (C) fluoroscopic en face view of the coronary sinus (CS) (red dotted circle). (D) S-curve of the CS depicting the angulations of the 2-chamber (yellow), 3-chamber (red), and 1-chamber (blue) views. The 2 eye symbols describe the position of the x-ray detector in the corresponding fluoroscopic view; orange corresponds to E and F and blue to G and H. (E) The MSCT axial slice is in the same orientation of F, which shows the ostium of the CS (red dashed line) in plane. The distal course of the CS is shown by the red asterisk. (G) The MSCT sagittal slice is in the same orientation of H, which shows the ostium of the CS in plane and its course, in a short-axis view.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-17.pptx"})' class="cursor-pointer">Figure 17).
Chamber view anatomy of the Coronary Sinus. (A) MSCT, (B) endovascular, and (C) fluoroscopic en face view of the coronary sinus (CS) (red dotted circle). (D) S-curve of the CS depicting the angulations of the 2-chamber (yellow), 3-chamber (red), and 1-chamber (blue) views. The 2 eye symbols describe the position of the x-ray detector in the corresponding fluoroscopic view; orange corresponds to E and F and blue to G and H. (E) The MSCT axial slice is in the same orientation of F, which shows the ostium of the CS (red dashed line) in plane. The distal course of the CS is shown by the red asterisk. (G) The MSCT sagittal slice is in the same orientation of H, which shows the ostium of the CS in plane and its course, in a short-axis view.
The two-chamber view of the right heart corresponds to a transthoracic echocardiographic parasternal long-axis two-chamber view of the right ventricle. Transesophageal echocardiography can display a similar two-chamber view in a mid-esophageal right ventricular inflow view at 100°-120° (bicaval angle, rotated toward the right), a low-esophageal right atrial view, or a transgastric right ventricular inflow (long-axis) view at 110°-130°.
This view is obtained by placing the C-arm in a RAO CRA angulation (average fluoroscopic angulation: RAO25°/CRA15°) . With the tricuspid valve in plane, it is possible to appreciate the attachments of the septal and posterior leaflets in a relative superior and inferior positioning on the fluoroscopic screen. In this view, the RVOT is elongated and can provide the correct path from tricuspid valve to pulmonary artery without foreshortening. Pulmonary and tricuspid valves annulus can be simultaneously in plane. This view allows to appreciate the ostium of the coronary sinus en-face. On transesophageal echocardiography, the right-heart three-chamber view corresponds to a transgastric view at 60°-90°.
This view can be obtained by placing the C-arm in a steep CRA angulation with variable RAO/LAO angulation (average fluoroscopic angulation: LAO5°/CRA60°) . An extreme cranial angulation with the tricuspid valve in plane allows operators to appreciate the attachments of the anterior and septal leaflets in a relative right to left positioning on the fluoroscopic screen. The four-chamber view can display the tricuspid valve annulus and atrial septum both in plane. Right and left ventricles are full separated with elongation of the interventricular septum useful for ventricular septal defect closure. The fluoroscopic four-chamber view corresponds to the classical apical four-chamber view on transthoracic echocardiography or mid-to-low esophageal view at 0°-20° on transesophageal echocardiography.
The RVOT-pulmonary artery view typically used during transcatheter pulmonary valve replacement and the bicaval view during transseptal punctures can be obtained in extreme LAO projections approaching the 1-chamber view of the right or left heart (Bicaval view. MSCT (A), fluoroscopic (B), conventional and modified TEE (C-D) and TEE Live 3D (E-F) bicaval matching views of the right atrium. The modified echocardiographic displays were inverted left\/right and rotated 90 clockwise from the classical TEE bicaval view. In this view the superior and inferior venae cavae (turquoise and orange circles, respectively) can be visualized both in plane as well as the inferior vena cava and the interatrial septum (green circle). The fluoroscopic is obtained by angulating the C-arm in a LAO90\u00b0\/CRA10\u00b0 projection. Tricuspid valve (violet circle) is \u201cen face\u201d and its anterior (yellow line), posterior (blue line) and septal (white line) leaflets are separated.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-16.pptx"})' class="cursor-pointer">Figure 16).
During transcatheter pulmonary valve replacements, physicians often select a lateral projection with shallow CRA angulation to obtain the best views of the right ventricle-to-pulmonary artery tract (Right ventricle outflow tract (RVOT)-pulmonary artery view. MSCT, fluoroscopic, conventional and modified transthoracic echocardiographic views of the RVOT and PA. The RVOT and the PA appear elongated and separated by the annulus of the pulmonary valve (PV) (white dotted line). The fluoroscopic is obtained by angulating the C-arm in a LAO90\u00b0\/CRA10\u00b0 projection. The conventional transgastric view was flipped upside-down to reproduce the MSCT and fluoroscopic views.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-18.pptx"})' class="cursor-pointer">Figure 18). Similar transesophageal echocardiographic views can be obtained from a high transesophageal window at 0° or from a deep transgastric window at 70°- 90°. Oriented more to the right, the bicaval view can be appreciated from a modified subcostal transthoracic view or from the classical mid- transesophageal bicaval view at 90°-110°.
Right ventricle outflow tract (RVOT)-pulmonary artery view. MSCT, fluoroscopic, conventional and modified transthoracic echocardiographic views of the RVOT and PA. The RVOT and the PA appear elongated and separated by the annulus of the pulmonary valve (PV) (white dotted line). The fluoroscopic is obtained by angulating the C-arm in a LAO90°/CRA10° projection. The conventional transgastric view was flipped upside-down to reproduce the MSCT and fluoroscopic views.
While fluoroscopic chamber views might facilitate pattern recognition for structural interventions, the orientation of cardiac structures can vary somewhat among patients. Nonetheless, cardiac structures, similar to coronary arteries, can be found in consistent fluoroscopic quadrants across patients. The utilization of 3D tomographic images for procedural planning allows per-patient individualized mapping of cardiac structures. Accordingly, specific fluoroscopic working angles might be planed based on anatomical and procedural characteristics. As mentioned above, an optimal fluoroscopic angle is such that the vector joining the x-ray source and the detector is orthogonal to the vector of the structure of interest (i.e. the en-face/axial view of the structure). Each CRA/CAU angulation of the C-arm can be adjusted by a corresponding RAO/LAO angulation maintaining orthogonality with the structure of interest. The optimal projection curve, also referred to “the line of perpendicularity” is a S-shaped curve consisting of continuous pairs of optimal C‐arm angulations (RAO/LAO vs. CRA/CAU) where a given structure is in plane. Table 1 lists the characteristics of an S-curve, which can be obtained for any cardiac structure with a representative plane (e.g., aortic valve, mitral valve, tricuspid valve, pulmonary valve, superior vena cava, inferior vena cava, coronary sinus, atrial septum, LVOT, or coronary ostia). Optimal projection curves for any cardiac structure or cardiac device, can be calculated by designated software using a mathematical model described in Equation defining an optimal projection curve. Given an en-face viewing angle of a structure, it is possible to derive an optimal projection curve representing all the combinations of view angles in which the structure is seen in plane (perpendicular to its axis of symmetry) by the shown equation where: \u2205 is the cranio-caudal angle of the optimal projection curve at RAO\/LAO angle \u03b8 and; \u2205 en-face and \u03b8 en-face are respectively the CRA\/CAU and RAO\/LAO angles of the structure viewed en-face. Alternatively, optimal projection curves can be generated from two random perpendicular views of the structure, instead of one en-face view.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-19.pptx"})' class="cursor-pointer">Figure 19 . Optimal projection curves differ from one structure to another depending on spatial orientation (Optimal projection curves. An optimal projection curve is a S-shaped curve consisting of continuous pairs of optimal C\u00c3\u00a2\u00e2\u0082\u00ac\u00c2\u0090arm projections in which the structure appears in plane (i.e. perpendicular to the operator). Optimal projection S-curves varies between different structures depending on their spatial orientation. Intersection points of two S-curves represents C-arm coordinates in which the two structure are projected in plane.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-20.pptx"})' class="cursor-pointer">Figure 20). Of note, the point of intersection between two S-curves represents C-arm coordinates in which the two structure are projected in plane. In others words, the optimal projection curve removes or mitigates the parallax of one or more structures (or cardiac devices) and allows for a more accurate geometric understanding between structures of interest.
Equation defining an optimal projection curve. Given an en-face viewing angle of a structure, it is possible to derive an optimal projection curve representing all the combinations of view angles in which the structure is seen in plane (perpendicular to its axis of symmetry) by the shown equation where: ∅ is the cranio-caudal angle of the optimal projection curve at RAO/LAO angle θ and; ∅ en-face and θ en-face are respectively the CRA/CAU and RAO/LAO angles of the structure viewed en-face. Alternatively, optimal projection curves can be generated from two random perpendicular views of the structure, instead of one en-face view.
Optimal projection curves. An optimal projection curve is a S-shaped curve consisting of continuous pairs of optimal Cââ¬Âarm projections in which the structure appears in plane (i.e. perpendicular to the operator). Optimal projection S-curves varies between different structures depending on their spatial orientation. Intersection points of two S-curves represents C-arm coordinates in which the two structure are projected in plane.
Optimal projection curves can be used for planning of structural and coronary procedures. For instance, tracing the en-face view of the aortic annulus on MSCT permits instant generation of the optimal projection or S-curve by automated software. The S-curve will provide the operator with all viewing angles of the aortic annulus in plane and is critical for correct transcatheter aortic valve implantation depth. A similar approach can be adopted for any intervention that consists of placing a device across an anatomical structure [e.g., left atrial appendage closure, transcatheter mitral/pulmonary valve replacement, ostial left main or right coronary artery stenting].
Cardiac structures with similar orientations in the body (e.g. mitral and tricuspid valve or left atrial appendage and atrial septum) will have similarly shaped S-curves. Any S-curve can only intersect 3 of the 4 fluoroscopic quadrants – the non-intersecting quadrant defines the structure en-face or in short-axis while the 3 intersecting quadrants have the structure in plane. The distance between 2 structures’ S-curves describes the relative angle between the planes of the 2 structures. Thus, 2 structures with overlapping S-curves lie in the same plane. On the other hand, 2 structures with S-curves at right angle, would suggest that the 2 planar structures lie at 90 degrees to each other.
Furthermore, the shape of an S-curve provides valuable information about the orientation of the structure in the body. For example, a vertical annulus synonymous with a horizontal root will be associated with a more vertical S-curve whereas a horizontal annulus synonymous with a vertical root will be associated with a more horizontal S-curve (The slope of the S-curve represented by the aortic annulus. The shape and slope of a structure-specific S-curve is determined by the orientation of this particular structure in the body. A steep slope of the aortic annulus S-curve defines a vertical annulus plane, whereas a shallow slope defines a horizontal annulus plane. The middle scenario represents the most common situation where the S-curve has a more \u2018neutral\u2019 slope .<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-21.pptx"})' class="cursor-pointer">Figure 21). The orientation of the tangent to the S-curve will simulate the orientation of the plane of the structure on the fluoroscopic screen. In other words, a "horizontal" S-curve will produce "horizontal" tangents and therefore the orientation of the structure will lie horizontal on the fluoroscopic screen (The slope of the S-curve represented by the aortic annulus. The shape and slope of a structure-specific S-curve is determined by the orientation of this particular structure in the body. A steep slope of the aortic annulus S-curve defines a vertical annulus plane, whereas a shallow slope defines a horizontal annulus plane. The middle scenario represents the most common situation where the S-curve has a more \u2018neutral\u2019 slope .<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-21.pptx"})' class="cursor-pointer">Figure 21). It is possible, therefore, that the orientation of the cardiac structure ("horizontal" vs. "vertical") varies according to C-arm angulations depending on the changing slope of the S-curve. This information can help the operator to better understand the orientation of cardiac structures across the fluoroscopic grid.
The slope of the S-curve represented by the aortic annulus. The shape and slope of a structure-specific S-curve is determined by the orientation of this particular structure in the body. A steep slope of the aortic annulus S-curve defines a vertical annulus plane, whereas a shallow slope defines a horizontal annulus plane. The middle scenario represents the most common situation where the S-curve has a more ‘neutral’ slope .
Aortic root anatomy/aortic annulus s-curve
The aortic root is the continuation of the LVOT, extending from the basal attachment points of the aortic valve leaflets to their peripheral attachment at the level of the sinotubular junction . It is made of three components: 1) the valvular leaflets; 2) the fibrous interleaflet triangles; and 3) the sinuses of Valsalva. The three leaflets form the limits of the right, left, and non-coronary aortic sinuses. The aortic valve annulus is defined as the planar ring of tissue that unites the basal attachment points of the three aortic valve leaflets.
Obtaining the aortic annulus in-plane is critical for TAVI implantation depth and ancillary procedures such as commissural alignment, coronary access post-TAVI, BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction), and paravalvular leak closure.
During TAVI procedures, obtaining aortic annulus S-curve (i.e. as measured by pre-procedural MSCT) will provide the operator with all the viewing angles in which the aortic annulus appears in plane. A typical aortic annulus S-curve travels across the LAO CRA, shallow LAO CAU and RAO CAU quadrants while the short-axis view can be found in the extreme RAO CRA quadrant. Much less frequently, the en-face view of the aortic annulus is located in a steep LAO CAU angulation resulting in the S-curve intersecting the LAO CRA, shallow RAO CRA and RAO CAU quadrants.
As can be gleaned from the previous paragraph, the fluoroscopic location of the short-axis view of the aortic annulus (i.e., RAO CRA vs. LAO CAU) will impact the shape and position of the S-curve. Short-axis views closer to CRA/CAU 0 will generate vertical S-curves, and those approaching CRA/CAU 90 will generate horizontal S-curves (The slope of the S-curve represented by the aortic annulus. The shape and slope of a structure-specific S-curve is determined by the orientation of this particular structure in the body. A steep slope of the aortic annulus S-curve defines a vertical annulus plane, whereas a shallow slope defines a horizontal annulus plane. The middle scenario represents the most common situation where the S-curve has a more \u2018neutral\u2019 slope .<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-21.pptx"})' class="cursor-pointer">Figure 21). Short-axis views approaching RAO/LAO 0 will displace S-curves towards the periphery of the fluoroscopic grid, and those nearer to RAO/LAO 90 will push curves towards the center.
The aortic annulus S-curve, cusp/commissural anatomy – Across its trajectory from RAO CAU to LAO CRA, the aortic annulus S-curve reveals an alternating pattern of 3-cusp to 2-cusp overlap views with 3-, 2- and 4-chamber views, respectively (The aortic annulus S-curve and cusp\/commissural orientation. The orientation of the aortic valve cusps and commissures depends on the fluoroscopic projection used. This figure shows the cusp and commissural orientation from six different fluoroscopic views along the aortic annulus S-curve. The three most frequently used fluoroscopic projections are the R-L cusp overlap view (yellow), 3-cusp coplanar view (turquoise) and the R-N cusp overlap view (violet) \u2013 these projections also fall within easy reach of the table\/patient, whereas the other projections are typically only reached by using more extreme C-arm angulations. LAO, left anterior oblique; LCC, left coronary cusp; NCC, non-coronary cusp; RAO, right anterior oblique; RCC, right coronary cusp\u00a0<\/span>.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-22.pptx"})' class="cursor-pointer">Figure 22 - Video 1). The 3-cusp co-planar views can have a [non-, right-, left-] or a [right-, non-, left] orientation on the fluoroscopic screen from left to right in a very shallow LAO CAU or LAO CRA views, respectively. The 2-cusp overlap views can isolate the non-, left-, or right coronary cusps in the RAO CAU, LAO CRA and steep LAO CRA views, respectively. The isolated non- and right-coronary cusps are positioned to the left of the fluoroscopic screen, the isolated left coronary cusp to the right. The 2-cusp overlap views isolating the left or right coronary cusps offers optimal viewing angles of the left and right coronary ostia, respectively.
The aortic annulus S-curve and cusp/commissural orientation. The orientation of the aortic valve cusps and commissures depends on the fluoroscopic projection used. This figure shows the cusp and commissural orientation from six different fluoroscopic views along the aortic annulus S-curve. The three most frequently used fluoroscopic projections are the R-L cusp overlap view (yellow), 3-cusp coplanar view (turquoise) and the R-N cusp overlap view (violet) – these projections also fall within easy reach of the table/patient, whereas the other projections are typically only reached by using more extreme C-arm angulations. LAO, left anterior oblique; LCC, left coronary cusp; NCC, non-coronary cusp; RAO, right anterior oblique; RCC, right coronary cusp .
The 2-cusp overlap views can be useful for procedures that require commissural isolation: (i) the cusp overlap view isolating the non-coronary cusp places the commissure between the right and left coronary cusp to the right of the screen; (ii) the cusp overlap view isolating the right coronary cusp places the commissure between the left and non-coronary cusps to the right of the screen; and (iii) the cusp overlap view isolating the left coronary cusp places the commissure between the non- and right-coronary cusp to the left of the screen.
As we have described, there is an important association between S-curves, chamber views, and coronary cusp/artery anatomy that will be further discussed for TAVI and related procedures.
UTILITY OF AORTIC ANNULUS S-CURVE FOR TAVR AND RELATED PROCEDURES
Crossing the aortic valve - Crossing the aortic valve can be performed at any point along the S-curve of the aortic annulus in 3 general regions: RAO-CAU, AP, or LAO-CRA. Inspecting the calcium distribution along the aortic annulus S-curve may also reveal an optimal viewing angle for crossing, especially in cases with asymmetric calcium cusp deposition. This can be achieved by aligning the MSCT multiplanar reconstruction lines across the asymmetric calcium deposits while the annulus is in-plane. A maximal intensity projection can also be examined while scrolling through the S-curve to identify an optimal crossing view. In the absence of a MSCT (such as in the setting of balloon aortic valvuloplasty), the operator may perform a quick cinegram along a presumed S-curve (e.g., [RAO 30 CAU 30], [AP], and [LAO 30 CRA 30]) and select the best viewing angle that separates the calcium deposits and identifies the aortic valve orifice. Symmetric calcifications across the 3 cusps may render these techniques ineffective (Fluoroscopic projections along the S-curve and AV Crossing. The optimal fluoroscopic projection along the S-curve for AV crossing is the angle where calcium deposits separate in systole (right upper panel). The left lower panel shows good separation of calcium deposits (yellow dotted square) in a RAO\/CAU view (R-L cusp overlap view in this particular case, looking into the NCC-RCC and NCC-LCC commissures). In a near anteroposterior (AP) view (middle panel), the calcified RCC is positioned in front, which makes identification of the AV orifice difficult. In a LAO\/CRAN view (right lower panel), calcium deposits at the level of the R-L commissure do not separate optimally in this particular case. AV, aortic valve; LAO, left anterior oblique; LCC, left coronary cusp; NCC, non-coronary cusp; RAO, right anterior oblique; RCC, right coronary cusp; CRA, cranial\u00a0<\/span>.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-23.pptx"})' class="cursor-pointer">Figure 23). In patients with a bicuspid aortic valve (BAV), specific optimal projection views for valve crossing are based on the characteristic fusion of cusps and the calcification patterns. For example, with right and left cusp fusion, the best crossing view is in RAO-CAU (right-left cusp overlap view). The next most common is right and non-coronary cusp fusion that is best crossed in LAO-CRA (right and non-coronary cusp overlap view).
Fluoroscopic projections along the S-curve and AV Crossing. The optimal fluoroscopic projection along the S-curve for AV crossing is the angle where calcium deposits separate in systole (right upper panel). The left lower panel shows good separation of calcium deposits (yellow dotted square) in a RAO/CAU view (R-L cusp overlap view in this particular case, looking into the NCC-RCC and NCC-LCC commissures). In a near anteroposterior (AP) view (middle panel), the calcified RCC is positioned in front, which makes identification of the AV orifice difficult. In a LAO/CRAN view (right lower panel), calcium deposits at the level of the R-L commissure do not separate optimally in this particular case. AV, aortic valve; LAO, left anterior oblique; LCC, left coronary cusp; NCC, non-coronary cusp; RAO, right anterior oblique; RCC, right coronary cusp; CRA, cranial .
Pre- and post-dilation along the S-curve – The major and minor axis of the aortic annulus can be appreciated along the S-curve in AP (i.e., 1- and/or 2-chamber views) and RAO CAU (i.e., 3-chamber view) angulations, respectively (Impact of implantation view on perception of aortic arch, aortic annulus and LVOT. The aortic arch is typically more closed and the aortic annulus plane more horizontal in an R-L cusp overlap view (compared with a 3-cusp coplanar view). Working in an R-L cusp overlap view also typically shows the minor axis of the aortic annulus (translating into a 3-chamber view) and elongation of the LVOT, whereas a 3-cusp coplanar projection shows the major axis of the aortic annulus (translating into a 2-chamber view) and foreshortening of the LVOT (white rectangle). LAO, left anterior oblique; RAO, right anterior oblique; CRA, cranial; CAU, caudal; LVOT, left ventricle outflow tract\u00a0<\/span>.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-24.pptx"})' class="cursor-pointer">Figure 24). Aligning the multiplanar reconstruction lines across the major and minor axis will provide AP and RAO CAU angulations, respectively. The measurement of the minor axis can also be helpful for balloon sizing. By means of a 3-chamber view (RAO CAU) during pre-dilation for TAVI or stand-alone balloon aortic valvuloplasty, the operator may appreciate the minor axis of the aortic annulus during balloon inflation that provides visual feedback. Frame under expansion and post-dilation are usually best appreciated and performed in the RAO CAU view. As opposed to using the minor axis, pre- or post-dilation may be performed in the axis of maximal calcification where balloon or frame expansion may be most restricted . Furthermore, removing the nose cone of a self-expanding valve is best performed in the RAO CAU view as this displays the narrowest point that should be avoided by centralizing the cone.
Impact of implantation view on perception of aortic arch, aortic annulus and LVOT. The aortic arch is typically more closed and the aortic annulus plane more horizontal in an R-L cusp overlap view (compared with a 3-cusp coplanar view). Working in an R-L cusp overlap view also typically shows the minor axis of the aortic annulus (translating into a 3-chamber view) and elongation of the LVOT, whereas a 3-cusp coplanar projection shows the major axis of the aortic annulus (translating into a 2-chamber view) and foreshortening of the LVOT (white rectangle). LAO, left anterior oblique; RAO, right anterior oblique; CRA, cranial; CAU, caudal; LVOT, left ventricle outflow tract .
From Double-S curve to Cusp Overlap view – Parallax occurring from suboptimal C-arm angulations can affect the apparent implantation depth if either the annulus or delivery catheter is not in-plane. In turn, this can result in significant foreshortening of either structure leading to malpositioning and increased risk of paravalvular leak, conduction abnormalities, coronary artery obstruction, and valve embolization. Obtaining a co-planar view of the aortic annulus alone ignores the potential parallax that may occur with the delivery catheter. Balloon-expandable transcatheter aortic valves are commonly positioned and deployed perpendicular to the aortic valve annulus, using a 3-cusp co-planar view (non-, right-, left-coronary cusp). Self-expanding transcatheter aortic valves, however, engage from the outer aortic curvature and tend to land “non-coaxial” across the aortic annulus .
The “Double S curve” method aims to eliminate parallax between the aortic annulus and delivery catheter. The double S-curve method identifies the coordinate of intersection between the aortic annulus and delivery catheter S-curves. Step 1 – the S-curve of the aortic annulus, representing the perpendicular views of the annular plane, is generated using conventional computed tomography software. Step 2 – after advancing the delivery catheter across the aortic annulus, 2 perpendicular views of the delivery catheter radiopaque marker are recorded in LAO and RAO at least 30 degrees apart with necessary CRA/CAU angulations. The 2 perpendicular views generate the delivery catheter S-curve according to the previously described mathematical model. Step 3 – the fluoroscopic intersection between the aortic annulus and delivery catheter S-curves defines the optimal projection for implantation as it eliminates foreshortening by providing a co-planar view of the delivery catheter and aortic annulus (The \u201cdouble S-curve\u201d model for definition of optimal projection for TAVI. Step 1 (A) - The S-curve of the aortic valve annulus, representing the perpendicular views of the annular plan, is generated (FluoroCT software 1.1.1). Step 2 (B) - Two random projections (e.g. RAO and LAO) of the delivery catheter marker in plane (without parallax) are obtained during the procedure. Step 3 (C) - The two fluoroscopic coordinates are formulated to generate the S-curve of delivery catheter using the FluoroCT software 1.1.1. The coordinates of intersection between the two S-curves (red dot) are then defined as the optimal projection for implantation with a pre-set deviation \u201ctolerance\u201d of ~5% (green deltoid).<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-25.pptx"})' class="cursor-pointer">Figure 25). The double S-curve method can also be applied for valve-in-valve procedures. The first step is to obtain a closed-spline tracing of the bioprosthesis frame with ensuing steps as previously mentioned. In more than 90% of transfemoral TAVI cases, the coordinate of intersection between the aortic annulus and delivery catheter S-curves occurs in RAO CAU. This projection translates into a 3-chamber (or LVOT) view that offers several advantages (Double S-curve and implantation of self-expanding THVs. The intersection of the aortic annulus and transcatheter heart valve (THV) delivery system S-curves (which define both structures in plane) is in most cases situated in the RAO-CAUD quadrant (\u201cdouble S crossing point\u201d). In an ideal scenario, implantation of self-expanding THVs would be performed using this fluoroscopic projection; however, the fluoroscopic projection corresponding with the double S crossing point cannot be determined preprocedurally. When deploying self-expanding THVs in a (near) R-L cusp overlap view, one approximates this double S crossing point, inducing minimal THV parallax or tilt in the annular plane. The more one works in an LAO projection, the more the S-curves of the aortic annulus and THV delivery system separate, with the result that both structures are visualized in a different plane (thereby inducing a problem for accurate assessment of THV implantation depth). RAO, right anterior oblique; CAU, caudal; LAO, left anterior oblique\u00a0<\/span>.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-26.pptx"})' class="cursor-pointer">Figure 26):
The “double S-curve” model for definition of optimal projection for TAVI. Step 1 (A) - The S-curve of the aortic valve annulus, representing the perpendicular views of the annular plan, is generated (FluoroCT software 1.1.1). Step 2 (B) - Two random projections (e.g. RAO and LAO) of the delivery catheter marker in plane (without parallax) are obtained during the procedure. Step 3 (C) - The two fluoroscopic coordinates are formulated to generate the S-curve of delivery catheter using the FluoroCT software 1.1.1. The coordinates of intersection between the two S-curves (red dot) are then defined as the optimal projection for implantation with a pre-set deviation “tolerance” of ~5% (green deltoid).
Double S-curve and implantation of self-expanding THVs. The intersection of the aortic annulus and transcatheter heart valve (THV) delivery system S-curves (which define both structures in plane) is in most cases situated in the RAO-CAUD quadrant (“double S crossing point”). In an ideal scenario, implantation of self-expanding THVs would be performed using this fluoroscopic projection; however, the fluoroscopic projection corresponding with the double S crossing point cannot be determined preprocedurally. When deploying self-expanding THVs in a (near) R-L cusp overlap view, one approximates this double S crossing point, inducing minimal THV parallax or tilt in the annular plane. The more one works in an LAO projection, the more the S-curves of the aortic annulus and THV delivery system separate, with the result that both structures are visualized in a different plane (thereby inducing a problem for accurate assessment of THV implantation depth). RAO, right anterior oblique; CAU, caudal; LAO, left anterior oblique .
Possible limitations of the 3-chamber view include:
Depth verification across the left coronary cusp prior to complete release can be performed in LAO 35 CRA 20 where the left coronary cusp and left coronary artery are usually isolated on average along the S-curve. Upon complete deployment and release in the 3-chamber view, the self-expanding prosthesis tends to reorient itself towards the plane of the aortic annulus .
As a proxy to the “Double S-curve”, the “Cusp overlap view” has gained widespread acceptance as the most user-friendly method for implantation of self-expanding transcatheter aortic valves with good concordance between both methods . Balloon-expandable valves may also be deployed using similar methods .
Like the “Double S-curve”, the “Cusp overlap view” isolates the non-coronary cusp while overlapping the left and right coronary cusps in the RAO CAU angulation (Impact of implantation view on perception of aortic arch, aortic annulus and LVOT. The aortic arch is typically more closed and the aortic annulus plane more horizontal in an R-L cusp overlap view (compared with a 3-cusp coplanar view). Working in an R-L cusp overlap view also typically shows the minor axis of the aortic annulus (translating into a 3-chamber view) and elongation of the LVOT, whereas a 3-cusp coplanar projection shows the major axis of the aortic annulus (translating into a 2-chamber view) and foreshortening of the LVOT (white rectangle). LAO, left anterior oblique; RAO, right anterior oblique; CRA, cranial; CAU, caudal; LVOT, left ventricle outflow tract\u00a0<\/span>.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-24.pptx"})' class="cursor-pointer">Figure 24). As already described, the “Cusp overlap view” is acquired using the pre-procedural MSCT and rotating the multi-planar reconstruction line to transect the nadir of the non-coronary cusp; this will isolate the non-coronary cusp in all cases and overlap the right and left cusps in most cases depending on cusp symmetry.
Commissural and/or coronary alignment - The importance of coronary access after TAVI has inspired operators to obtain alignment between the commissural posts of the transcatheter aortic valve and native commissures (i.e., commissural alignment). Although unclear at this time, commissural alignment may also prove beneficial for valve hemodynamics, valve durability, and reinterventions in case of valve failure .
Given that the transcatheter aortic valve commissural posts are 120-degrees separated and the nadirs of the bioprosthetic leaflets are designed 60 degrees from each commissure, obtaining optimal commissural alignment implies that the right and left coronary artery ostia emerge at 60 degrees from the native right-left coronary cusp commissure. In this way, the coronary ostia will align with the nadirs of the bioprosthetic valve leaflets. If the coronary arteries emerge closer or further than 60 degrees from the native commissures, and the transcatheter aortic valve commissural post is aligned with the left-right commissure, a degree of misalignment will ensue. For these reasons, the concept of “coronary alignment” was recently proposed whereby the transcatheter aortic valve commissural post is centered between the coronary ostia irrespective of the native commissure; to be successful, the left and right coronary arteries must emerge at 120 degrees. An alternative option includes aligning the nadir of a bioprosthetic leaflet to a single coronary artery (e.g., left coronary artery) or positioning the transcatheter aortic valve commissural post 60 degrees relative to a single coronary artery. Analysis of the pre-procedural computed tomography scan can determine the relative angular distances between the commissures and coronary arteries and help select a commissural or coronary alignment strategy , , , .
“Commissural alignment” requires overlapping the left and right coronary cusp to isolate the commissure between these cusps to the right-side of the fluoroscopic screen while the aortic annulus remains co-planar (Implantation technique for obtaining patient-specific commissural Alignment. To obtain patient-specific commissural alignment during transcatheter aortic valve replacement, one can make use of the R-L cusp overlap view, in which the commissure between both cusps will be isolated and directed toward the right on fluoroscopy. Consequently, patient-specific commissural alignment will be obtained as follow: A) ACURATE Neo2 and C) Navitor: if one of the THV commissural posts can be lateralized at the right-hand side (with the 2 other THV commissural posts overlapping at the left-hand side in the R-L cusp overlap view). B) EVOLUT FX: one of the \u201cdots marker\u201d is lateralized at the right-hand side with the other two dots overlapping\/nearly overlapping at the left-hand side of the screen\u00a0<\/span>.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-27.pptx"})' class="cursor-pointer">Figure 27). The correct commissural post is then “aligned” with this commissure to the right of the fluoroscopic screen. Along the aortic annulus S-curve, overlap of the right and left coronary cusp is synonymous with the 3-chamber view (RAO CAU) or “right/left cusp overlap view” for depth implantation where the non-coronary cusp is isolated to the left-side of the fluoroscopic screen. Previous studies suggest that patient specific implantation techniques using the “right/left cusp overlap view” can achieve adequate commissural alignment (i.e., none or mild misalignment) in 90% of cases. Although successful commissural alignment can be achieved with self-expanding platforms, it is currently not feasible with their balloon-expandable counterpart. Technical details on how to perform “commissural alignment” using various transcatheter aortic valve designs (Evolut PRO, Medtronic USA; Acurate Neo2, Boston Scientific USA; Navitor, Abbott USA) is provided elsewhere .
Implantation technique for obtaining patient-specific commissural Alignment. To obtain patient-specific commissural alignment during transcatheter aortic valve replacement, one can make use of the R-L cusp overlap view, in which the commissure between both cusps will be isolated and directed toward the right on fluoroscopy. Consequently, patient-specific commissural alignment will be obtained as follow: A) ACURATE Neo2 and C) Navitor: if one of the THV commissural posts can be lateralized at the right-hand side (with the 2 other THV commissural posts overlapping at the left-hand side in the R-L cusp overlap view). B) EVOLUT FX: one of the “dots marker” is lateralized at the right-hand side with the other two dots overlapping/nearly overlapping at the left-hand side of the screen .
“Coronary alignment” requires a projection angle where the right and left coronary ostia are overlapped (i.e., “coronary ostia overlap view”) to the right-side of the fluoroscopic screen. In this view, the dedicated commissural post is positioned to the right of the screen. Previous studies have shown that the “right/left cusp overlap view” is in the RAO CAU quadrant of the aortic annulus S-curve in 87% of tricuspid and 93% of bicuspid aortic valves. In comparison, there was a higher proportion of patients with the “right/left coronary overlap view” in the RAO CAU quadrant (95% and 97% for tricuspid and bicuspid aortic valves, respectively). More specifically, there was less than a 10-degree angular difference in 3 out of 4 patients. In most cases (~75%), the “coronary ostia overlap view” is located in a steeper RAO/CAU view than the “right/left coronary cusp overlap” view.
Coronary access post-TAVI – A study of 449 acute coronary syndrome patients documented a high rate (~98%) of successful coronary angiography post TAVI (defined as sufficient visualization of the vessel with either selective or non-selective engagement of the coronary ostium). In 21 of 243 patients (8.6%), PCI was unsuccessful. Non-selective coronary engagement was more common for the right than left coronary artery (30% vs. 21%), coronary angiography and PCI was more successful with short-framed balloon-expandable prostheses than tall-framed self-expanding prostheses. Two or more catheters were required in 10-20% of patients . A similar study, RE-ACCESS (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent), reported a 7.7% rate of unsuccessful coronary cannulation. The use of Evolut transcatheter valve, device implant depth, and transcatheter heart valves oversized with respect to the sinus of Valsalva were independent predictors of unsuccessful coronary cannulation .
Many factors can influence coronary access post-TAVI, including native coronary ostial height, sinus of Valsalva width, coronary ostial eccentricity, transcatheter aortic valve design (tall vs. short, narrow vs. wide, intra-annular vs. supra-annular designs), transcatheter aortic valve commissural alignment, implantation depth, operator experience, and fluoroscopic viewing angle for coronary intubation. Optimal fluoroscopic viewing projections of the coronary ostia can facilitate their evaluation, intubation, and intervention (Optimal Fluoroscopic Views to Expose the Coronary Ostia\/Coronary Access. The first method is based on fluoroscopic isolation of the right and left coronary ostia, projecting the RCA ostium at the left-hand side and the LCA ostium at the right-hand side, respectively. In the second method, one determines the fluoroscopic projection in which the S-curves of the aortic annulus plane and RCA\/LCA ostium intersect, projecting both the aortic annulus and RCA\/LCA ostium in plane. RCA: right coronary artery, LCA: left coronary artery\u00a0<\/span>.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-28.pptx"})' class="cursor-pointer">Figure 28).
Optimal Fluoroscopic Views to Expose the Coronary Ostia/Coronary Access. The first method is based on fluoroscopic isolation of the right and left coronary ostia, projecting the RCA ostium at the left-hand side and the LCA ostium at the right-hand side, respectively. In the second method, one determines the fluoroscopic projection in which the S-curves of the aortic annulus plane and RCA/LCA ostium intersect, projecting both the aortic annulus and RCA/LCA ostium in plane. RCA: right coronary artery, LCA: left coronary artery .
An S-curve can be developed for depicting numerous views of the coronary ostia in-plane. Ideally, however, a co-planar view of the aortic anulus and coronary ostia would mitigate foreshortening of the aortic root and improve visibility during contrast injections. Utilizing the double S-curve between the coronary ostia and aortic annulus, our group reported the ideal fluoroscopic projections of the left (LAO 37°, CRA 22°, 95% CI: LAO 33°-40°, CRA 19°-25°) and right coronary ostia (LAO 79°, CRA 41°, 95% CI: LAO 74°-84°, CRA 37°-45°) . For the ostial right coronary, the data suggest that ideal angulations may not be achievable in most patients due to C-arm constraints – nonetheless, operators should strive for a steep LAO and shallow CRA angulation. The double S-curve between the left coronary ostium and aortic annulus isolates the left coronary cusp, while the double S-curve between the right coronary ostium and aortic annulus isolates the right coronary cusp. In other words, by isolating the left coronary cusp (i.e., 2 cusp non-right overlap view in LAO CRA) and right coronary cusp (i.e., 2 cusp non-left overlap view in steep LAO CRA), optimal viewing angles of the left main and right coronary ostia, respectively, can be obtained, thereby avoiding the need for double S-curve software programs.
Optimal views of the left and right coronary ostia can be useful for ruling out coronary obstruction after TAVI. Furthermore, these views can facilitate selective coronary engagement by isolating the coronary ostia and increasing the likelihood of co-axial stent strut engagement. Non-optimal viewing angles may lead the operator to enter a non-coaxial stent strut resulting in poor guide catheter support and need for “fishing technique” with a hydrophilic wire or mother-in-child catheters. The “snorkel technique” (whereby a stent is implanted across the coronary ostium with protrusion into the aorta) can also be supported by optimal coronary ostial viewing projections.
BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent coronary artery obstruction)
TAVI can displace the native aortic valve leaflets towards the coronary ostia resulting in coronary obstruction. BASILICA is a technique to prevent coronary obstruction during TAVI by using an electrified wire to lacerate the left or right aortic valve leaflet from its base to free edge, producing a V-shaped splayed leaflet that promotes coronary blood flow . During the procedure, the target leaflet traversal point and traversal direction need to be appreciated. An appropriate trajectory for leaflet traversal is necessary to maximize the laceration-related “triangle of flow” and prevent mechanical injury to adjacent tissues (e.g., anterior mitral valve leaflet). To best understand the trajectory of laceration, a central and side view of the intended leaflet is necessary (Planning for BASILICA-assisted valve-in-valve transcatheter aortic valve replacement. Transcatheter electrosurgical aortic leaflet laceration (BASILICA [bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction]) is an interventional technique to prevent coronary artery obstruction. An essential step in preprocedural planning for this procedure is determining the \u201cside view\u201d and \u201ccentral view\u201d of the leaflet to be lacerated; this can be achieved by understanding cusp and commissural orientation along the aortic annulus S-curve. The side view is used to assess the depth of the catheter in the target leaflet, the correct orientation of the catheter toward the leaflet, and wire traversal through the leaflet. The central view is used to guide catheter manipulation to achieve a position in the center of the leaflet. Partially reproduced with permission from Komatsu et al .<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-29.pptx"})' class="cursor-pointer">Figure 29). In other words, the BASILICA procedure requires a 3-cusp co-planar view of the aortic annulus that centralizes the intended leaflet (i.e., central view) and a 2-cusp overlap view that isolates it (i.e., side view). For example, the central view of the left coronary cusp would represent a 3-cusp co-planar view with non-left-right orientation of the cusps from left to right on the fluoroscopic screen. The side view of the left coronary cusp would represent a non-right cusp overlap view with the isolated left coronary leaflet to the right of the fluoroscopic screen.
Planning for BASILICA-assisted valve-in-valve transcatheter aortic valve replacement. Transcatheter electrosurgical aortic leaflet laceration (BASILICA [bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction]) is an interventional technique to prevent coronary artery obstruction. An essential step in preprocedural planning for this procedure is determining the “side view” and “central view” of the leaflet to be lacerated; this can be achieved by understanding cusp and commissural orientation along the aortic annulus S-curve. The side view is used to assess the depth of the catheter in the target leaflet, the correct orientation of the catheter toward the leaflet, and wire traversal through the leaflet. The central view is used to guide catheter manipulation to achieve a position in the center of the leaflet. Partially reproduced with permission from Komatsu et al .
Komatsu et al . have elegantly documented the distribution of C-arm projections in native and bioprosthetic aortic valve cusps with median (interquartile range) central and side fluoroscopic angulations as follows: non-coronary cusp - LAO 59° (47°–70°) CRA 36° (29°–43°) and RAO 11° (3°–24°) CAU 25° (15°–35°), right coronary cusp - LAO 13° (2°–19°) CAU 2° (−14°–4°) and RAO 83° (69°–100°) CAU 46° (39°–52°), left coronary cusp - RAO 43° (31°–60°) CAU 41° (33°–51°) and LAO 31° (24°–41°) CRA 20° (8°–26°). In the same study, the authors identified achievable C-arm angulations for the right coronary cusp front and side views in 100% and 7.8% of patients, and for the left coronary cusp front and side views in 99.2% and 47.6%. They concluded that a right cusp BASILICA procedure would be more challenging due to the hostile C-arm angulations. Tilting the patient’s shoulders towards the right and back may alleviate the problem of the right coronary cusp side view but may also sabotage the pre-determined working angles and worsen the right coronary cusp central views.
Paravalvular leak closure
MSCT can facilitate percutaneous PVL closure after TAVI or surgical aortic valve replacement by identifying the optimal fluoroscopic viewing angle along the aortic annulus S-curve for crossing and device implantation (Optimal fluoroscopic view for PVL plugging. Following localization using transesophageal echocardiographic (TEE) imaging, the paravalvular leak (PVL) origin can be identified and<\/span><\/p>\r\n labeled in the short-axis aortic annular plane viewed on cardiac computed tomography (CT). The optimal fluoroscopic projection for crossing and plugging can be determined by identifying a fluoroscopic view perpendicular to the PVL origin, thereby isolating (or lateralizing) the PVL origin. This figure illustrates an NCC-located PVL, which could be easily crossed and successfully closed using a fluoroscopic view perpendicular to the PVL origin (ie, a near R-L cusp overlap view, resulting in lateralization of the NCC)\u00a0<\/span>.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-30.pptx"})' class="cursor-pointer">Figure 30
Optimal fluoroscopic view for PVL plugging. Following localization using transesophageal echocardiographic (TEE) imaging, the paravalvular leak (PVL) origin can be identified and
labeled in the short-axis aortic annular plane viewed on cardiac computed tomography (CT). The optimal fluoroscopic projection for crossing and plugging can be determined by identifying a fluoroscopic view perpendicular to the PVL origin, thereby isolating (or lateralizing) the PVL origin. This figure illustrates an NCC-located PVL, which could be easily crossed and successfully closed using a fluoroscopic view perpendicular to the PVL origin (ie, a near R-L cusp overlap view, resulting in lateralization of the NCC) .
In recent years, there has been a growing interest to better understand the transseptal puncture with respect to procedures that target structures within the left atrium (e.g., left atrial appendage, mitral valve, pulmonary veins).
Atrial septum anatomy and atrial septum s-curve
The fossa ovalis is a depression in the right atrial aspect of the atrial septum. It represents the true interatrial portion and the thinnest part of the septum. Structures surrounding the atrial septum include: 1) the inferior vena cava (right inferior-posterior); 2) the infolding of the atrial septum (right superior-posterior); 3) the coronary sinus (left anterior-inferior); and 4) the noncoronary cusp of the aortic valve (left superior-anterior) .
Using MSCT, the contours of the fossa ovalis can be traced to generate an S-curve and can provide the operator with important information about the orientation of the atrial septum in the body (i.e., vertical or horizontal) and its location relative to target structures of interest (e.g., left atrial appendage, mitral valve). The typical atrial septum S-curve transects the RAO CRA, LAO CRA, and LAO CAU quadrants of the fluoroscopic grid; it is in these quadrants where the atrial septum is appreciated in plane (Atrial septum S-curve<\/span>. <\/span><\/strong>The typical atrial septum S-curve transects the RAO CRA, LAO CRA, and LAO CAU quadrants of the fluoroscopic grid; it is in these quadrants where the atrial septum is appreciated in plane.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-31.pptx"})' class="cursor-pointer">Figure 31). Given its orientation from a right posteroinferior to left anterosuperior direction, the en-face view of the atrial septum can be appreciated in a RAO/CAU view (i.e., right heart 2-chamber or left heart 3-chamber view) (Atrial septum en face view. Computed tomographic and fluoroscopic en-face view (blue dot) of the atrial septum can be appreciated in a RAO\/CAU projection (i.e., right heart 2-chamber or left heart 3-chamber view.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-32.pptx"})' class="cursor-pointer">Figure 32). In RAO CAU, there is maximal separation between the en-face view of the atrial septum and the aortic root; a transseptal needle would appear traveling into the screen and is an optimal view to confirm avoidance of the aortic root. From a transesophageal perspective, the 2-chamber of the right and 3-chamber of the left heart are separated by an anterior to posterior displacement of the ultrasound probe.
Atrial septum S-curve. The typical atrial septum S-curve transects the RAO CRA, LAO CRA, and LAO CAU quadrants of the fluoroscopic grid; it is in these quadrants where the atrial septum is appreciated in plane.
Atrial septum en face view. Computed tomographic and fluoroscopic en-face view (blue dot) of the atrial septum can be appreciated in a RAO/CAU projection (i.e., right heart 2-chamber or left heart 3-chamber view.
Atrial enlargement (i.e., right, left or biatrial) can change the attitudinal orientation of the atrial septum and therefore influence the shape of the atrial septum S-curve (Atrial septum S-curves. Atrial enlargement (i.e., right, left or biatrial) can change the attitudinal orientation of the atrial septum and therefore influence the shape of the atrial septum S-curve. A vertical atrial septum orientation will be represented by a vertical atrial septum s-curve. A horizontal atrial septum will translate into a horizontal atrial septum s-curve.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-33.pptx"})' class="cursor-pointer">Figure 33). In those cases with a vertical atrial septum the transseptal needle will need a generous curve and point from left to right on the fluoroscopic screen, while in cases of a horizontal atrial septum the needle will require less curvature as it points from inferior to superior on the screen (Atrial septum S-curve and fluoroscopic orientation for transeptal puncture. The orientation of the atrial septum is best appreciated in the LAO-CAU bicaval view. Vertical S-curve will translate into vertical atrial septum on the fluoroscopic screen; therefore, the needle will need a generous curve and point from left to right on the screen. Horizontal S-curve will translate into horizontal atrial septum, the needle will require less curvature as it points from inferior to superior on the fluoroscopic screen. TSP: transseptal puncture. AS: atrial septum. LAO-CAU: left anterior oblique-caudal.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-34.pptx"})' class="cursor-pointer">Figure 34).
Atrial septum S-curves. Atrial enlargement (i.e., right, left or biatrial) can change the attitudinal orientation of the atrial septum and therefore influence the shape of the atrial septum S-curve. A vertical atrial septum orientation will be represented by a vertical atrial septum s-curve. A horizontal atrial septum will translate into a horizontal atrial septum s-curve.
Atrial septum S-curve and fluoroscopic orientation for transeptal puncture. The orientation of the atrial septum is best appreciated in the LAO-CAU bicaval view. Vertical S-curve will translate into vertical atrial septum on the fluoroscopic screen; therefore, the needle will need a generous curve and point from left to right on the screen. Horizontal S-curve will translate into horizontal atrial septum, the needle will require less curvature as it points from inferior to superior on the fluoroscopic screen. TSP: transseptal puncture. AS: atrial septum. LAO-CAU: left anterior oblique-caudal.
Transseptal puncture is typically guided by two transesophageal echocardiographic views: (1) short-axis and (2) bicaval views (Orientation of bicaval and short-axis views for transseptal puncture. Transseptal puncture is typically guided by two transesophageal echocardiographic views:(1) short-axis and (2) bicaval views.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-35.pptx"})' class="cursor-pointer">Figure 35). By cross-referencing these views with MSCT, the operator may have a better understanding of the anatomical patterns and mechanics behind transseptal punctures.
Orientation of bicaval and short-axis views for transseptal puncture. Transseptal puncture is typically guided by two transesophageal echocardiographic views:(1) short-axis and (2) bicaval views.
MSCT multiplanar reconstructions with fluoroscopic simulations can help clarify the anatomical considerations associated with the short axis and bicaval views during transseptal puncture. Transecting the en-face view of the atrial septum across the short-axis plane of the aortic valve in a left-sided 3-chamber view will generate the transesophageal short-axis view. Fluoroscopically, this corresponds to an extreme RAO CRA viewing angle where the atrial septum is in plane and the aortic valve is seen en-face (i.e., the intersection of the atrial septum S-curve and en-face viewing angle of the aortic valve) (Short-axis (blue) and bicaval (green) views of the AS in transesophageal echocardiography, MSCT and fluoroscopic view. S-curve of the AS depicting the angulations of the short-axis (blue circle) and bicaval (green circle) views.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-36.pptx"})' class="cursor-pointer">Figure 36). The simulated fluoroscopic images of the short-axis view will reveal that the mitral valve is practically in plane and explains why “posterior punctures” result in greater heights above the mitral valve (Short axis view of the aortic valve during transeptal puncture for mitral procedures. Due to the orientation between the atrial septum (pink circle) and mitral valve (turquoise circle), a posterior puncture relative to the aortic valve, will result in a higher position relative to the mitral valve plane than an anterior puncture. LAA \u2013 left atrial appendage.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-37.pptx"})' class="cursor-pointer">Figure 37, The video shows the relation between transseptal puncture height (infero-superior aspect) with mitral valve height (antero-posterior aspect). The atrial septum (pink circle) and mitral valve (turquoise circle) are sequentially depicted in bicaval (LAO-CAU), short axis of the aortic valve (RAO-CRA), and 4-chamber view (LAO-CRA). Despite two similarly appearing punctures on the bicaval view (i.e. superior punctures), the anterior (yellow dot) and posterior (red dot) punctures from the short axis perspective translate into low and high heights from the mitral valve plane.\u00a0 \u00a0<\/span><\/span><\/p>","mediaType":"video","mediaMimeType":"video\/mp4","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_VIDEO-2.pptx"})' class="cursor-pointer">Video 2, The video shows the relation between transseptal puncture height (infero-superior aspect) with mitral valve height (antero-posterior aspect). The atrial septum (pink circle) and mitral valve (turquoise circle) are sequentially depicted in bicaval (LAO-CAU), and four chamber view (LAO-CRA). Despite two different appearing punctures on the bicaval view (i.e. superior and inferior punctures), the superior (red dot) and inferior (green dot) punctures from the four 4-chamber perspective translate into a same\/nearly same height from the mitral valve plane.<\/span><\/p>","mediaType":"video","mediaMimeType":"video\/mp4","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_VIDEO-3.pptx"})' class="cursor-pointer">Video 3). It can also be appreciated from the 3-chamber view that the transseptal height above the mitral valve can be influenced by the location of the short-axis cut across the aortic root (Relation between transseptal puncture height and location of the short axis view. 3-chamber view (MSCT) showing how the transseptal height above the mitral valve (purple circle) can be influenced by the location of the short-axis cut across the aortic root. The turquoise line represents a short-axis view closer to the base of the aortic annulus (yellow circle). The green line represents a short-axis view closer to the STJ (orange circle). A short axis view closer to the aortic annulus will translate into a shallower puncture (turquoise dotted line) than a puncture obtained with a short axis view at STJ level (green dotted line). STJ: sinotubular junction, AA: aortic annulus.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-38.pptx"})' class="cursor-pointer">Figure 38). In other words, short-axis views closer to the base of the aortic annulus will result in shallower transseptal heights relative to the mitral valve than those closer to the sinutubular junction or at the tips of the aortic valve leaflets. The fluoroscopic images also demonstrate that the left atrial appendage is located relatively anterior to the atrial septum and requires a “posterior puncture” to become more co-axial during its occlusion (Transseptal puncture for left atrial appendage (LAA) closure. Due to the orientation between the atrial septum and LAA orifice (the LAA is anterior to the atrial septum), a posterior puncture relative to the aortic valve will provide a more coaxial and central orientation towards the LAA orifice. Pink circle (atrial septum), green circle (LAA orifice), red dot (anterior puncture), turquoise dot (posterior puncture).<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-39.pptx"})' class="cursor-pointer">Figure 39).
Short-axis (blue) and bicaval (green) views of the AS in transesophageal echocardiography, MSCT and fluoroscopic view. S-curve of the AS depicting the angulations of the short-axis (blue circle) and bicaval (green circle) views.
Short axis view of the aortic valve during transeptal puncture for mitral procedures. Due to the orientation between the atrial septum (pink circle) and mitral valve (turquoise circle), a posterior puncture relative to the aortic valve, will result in a higher position relative to the mitral valve plane than an anterior puncture. LAA – left atrial appendage.
Relation between transseptal puncture height and location of the short axis view. 3-chamber view (MSCT) showing how the transseptal height above the mitral valve (purple circle) can be influenced by the location of the short-axis cut across the aortic root. The turquoise line represents a short-axis view closer to the base of the aortic annulus (yellow circle). The green line represents a short-axis view closer to the STJ (orange circle). A short axis view closer to the aortic annulus will translate into a shallower puncture (turquoise dotted line) than a puncture obtained with a short axis view at STJ level (green dotted line). STJ: sinotubular junction, AA: aortic annulus.
Transseptal puncture for left atrial appendage (LAA) closure. Due to the orientation between the atrial septum and LAA orifice (the LAA is anterior to the atrial septum), a posterior puncture relative to the aortic valve will provide a more coaxial and central orientation towards the LAA orifice. Pink circle (atrial septum), green circle (LAA orifice), red dot (anterior puncture), turquoise dot (posterior puncture).
The video shows the relation between transseptal puncture height (infero-superior aspect) with mitral valve height (antero-posterior aspect). The atrial septum (pink circle) and mitral valve (turquoise circle) are sequentially depicted in bicaval (LAO-CAU), short axis of the aortic valve (RAO-CRA), and 4-chamber view (LAO-CRA). Despite two similarly appearing punctures on the bicaval view (i.e. superior punctures), the anterior (yellow dot) and posterior (red dot) punctures from the short axis perspective translate into low and high heights from the mitral valve plane.
The video shows the relation between transseptal puncture height (infero-superior aspect) with mitral valve height (antero-posterior aspect). The atrial septum (pink circle) and mitral valve (turquoise circle) are sequentially depicted in bicaval (LAO-CAU), and four chamber view (LAO-CRA). Despite two different appearing punctures on the bicaval view (i.e. superior and inferior punctures), the superior (red dot) and inferior (green dot) punctures from the four 4-chamber perspective translate into a same/nearly same height from the mitral valve plane.
The 2-chamber view of the right heart displays the atrial septum en-face while the superior vena cava and inferior vena cava run relatively above and below it albeit the former lying slightly more anterior than the latter. Transecting the en-face view of the atrial septum from superior vena cava to inferior vena cava will generate the bicaval view. Translating this multiplanar reconstruction line towards the tricuspid valve will result in a 1-chamber view of the right and left heart with the tricuspid and mitral valves in short-axis or en-face view (i.e., LAO CAUD, 1-chamber view of the right and left heart) (Bicaval view. A) MSCT with multiplanar reconstruction transecting the en-face view of the atrial septum from superior to inferior vena cava. B) fluoroscopic simulation translating the multiplanar reconstruction line towards the tricuspid valve will result in a 1-chamber view of the right and left heart with the tricuspid (violet circle) and mitral (blue circle) valves in short-axis or en-face view (i.e., LAO CAUD, 1-chamber view of the right and left heart. <\/span>MSCT \u2013 multislice computed tomography, turquoise circle: superior vena cava, orange circle: inferior vena cava, green line: atrial septum, white line (septal leaflet), yellow line (anterior leaflet), light blue line (posterior leaflet).<\/span><\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-40.pptx"})' class="cursor-pointer">Figure 40). The simulated bicaval fluoroscopic view demonstrates the overlap with the 1-chamber view of the right and left heart in LAO CAU projection. The fluoroscopic bicaval view provides a wealth of information about catheter manipulations in the superior/inferior and anterior/posterior directions required during transcatheter tricuspid interventions and transseptal punctures for transcatheter mitral valve interventions and left atrial appendage occlusion (Fluoroscopic bicaval view for transcatheter procedures. Clip delivery system is simulated for transcatheter tricuspid valve edge-to-edge repair. The fluoroscopic bicaval view provides a wealth of information about catheter manipulations in the superior (pushing toward the atrial septum [green circle]), inferior (pulling toward posteroseptal commissure, anterior (counter clockwise rotation) and posterior (clockwise rotation) directions required during transcatheter tricuspid interventions for transcatheter mitral valve interventions. Circles represent: turquoise: superior vena cava, yellow: inferior vena cava, green: atrial septum, violet: tricuspid valve.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-41.pptx"})' class="cursor-pointer">Figure 41). The simulated fluoroscopic bicaval view highlights the relative superior and inferior locations of the lateral and medial commissures of the mitral valve relative to the atrial septal plane. An extension of this describes the superior to inferior layout of the A1-P1, A2-P2, and A3-P3 segments of the mitral valve. A superior to inferior displacement of the transseptal needle in the bicaval view translates to “hovering” across the segments of the mitral valve from A1-P1 to A3-P3, respectively (MSCT and fluoroscopic bicaval view relative to mitral valve. The simulated fluoroscopic bicaval view highlights the relative superior and inferior locations of the lateral and medial commissures of the mitral valve relative to the atrial septal plane. An extension of this describes the superior to inferior layout of the A1-P1 (yellow dots), A2-P2 (red dots), and A3-P3 (orange dots) segments of the mitral valve. Pink circle represents the atrial septum, turquoise circle represents the mitral valve. MSCT: multislice computed tomography.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-42.pptx"})' class="cursor-pointer">Figure 42). A mid-to-superior puncture tends to “centralize” catheters above the mitral valve while retaining the ability to flex and access the A3-P3 segments (Relation between infero-superior aspect of transeptal puncture and mitral valve commissures. An example of superior transeptal puncture for transcatheter mitral edge-to-edge repair is provided. The simulated fluoroscopic bicaval view highlights the relative superior and inferior locations of the lateral and medial commissures of the mitral valve relative to the atrial septal plane. A puncture closer to the superior vena cava will translate into a closer catheter position to the right trigone\/A2 which facilitates catheter manipulation over the mitral valve. A puncture closer to the inferior vena cava will translate into a closer catheter position to the medial commissure which facilitates catheter direction towards the lateral commissure but may hinder catheter manipulation over the mitral valve.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-43.pptx"})' class="cursor-pointer">Figure 43). Inferior punctures will provide a “bicommissural” path across the major axis of the mitral valve, co-axiality to the lateral commissure, and LAA.
Bicaval view. A) MSCT with multiplanar reconstruction transecting the en-face view of the atrial septum from superior to inferior vena cava. B) fluoroscopic simulation translating the multiplanar reconstruction line towards the tricuspid valve will result in a 1-chamber view of the right and left heart with the tricuspid (violet circle) and mitral (blue circle) valves in short-axis or en-face view (i.e., LAO CAUD, 1-chamber view of the right and left heart. MSCT – multislice computed tomography, turquoise circle: superior vena cava, orange circle: inferior vena cava, green line: atrial septum, white line (septal leaflet), yellow line (anterior leaflet), light blue line (posterior leaflet).
Fluoroscopic bicaval view for transcatheter procedures. Clip delivery system is simulated for transcatheter tricuspid valve edge-to-edge repair. The fluoroscopic bicaval view provides a wealth of information about catheter manipulations in the superior (pushing toward the atrial septum [green circle]), inferior (pulling toward posteroseptal commissure, anterior (counter clockwise rotation) and posterior (clockwise rotation) directions required during transcatheter tricuspid interventions for transcatheter mitral valve interventions. Circles represent: turquoise: superior vena cava, yellow: inferior vena cava, green: atrial septum, violet: tricuspid valve.
MSCT and fluoroscopic bicaval view relative to mitral valve. The simulated fluoroscopic bicaval view highlights the relative superior and inferior locations of the lateral and medial commissures of the mitral valve relative to the atrial septal plane. An extension of this describes the superior to inferior layout of the A1-P1 (yellow dots), A2-P2 (red dots), and A3-P3 (orange dots) segments of the mitral valve. Pink circle represents the atrial septum, turquoise circle represents the mitral valve. MSCT: multislice computed tomography.
Relation between infero-superior aspect of transeptal puncture and mitral valve commissures. An example of superior transeptal puncture for transcatheter mitral edge-to-edge repair is provided. The simulated fluoroscopic bicaval view highlights the relative superior and inferior locations of the lateral and medial commissures of the mitral valve relative to the atrial septal plane. A puncture closer to the superior vena cava will translate into a closer catheter position to the right trigone/A2 which facilitates catheter manipulation over the mitral valve. A puncture closer to the inferior vena cava will translate into a closer catheter position to the medial commissure which facilitates catheter direction towards the lateral commissure but may hinder catheter manipulation over the mitral valve.
Potential useful chamber views and fluoroscopic angulations for the guidance of transcatheter procedures targeting the mitral valve are summarized in Table 2.
The mitral valve has 2 major leaflets commonly described as being anterosuperior (or aortic) and posteroinferior (or mural) . The Carpentier classification recognizes 3 scallops in the mural leaflet (P1 to P3) and 3 corresponding segments in the aortic leaflet (A1 to A3) . According to an attitudinal approach and using the central segment (A2-P2) as reference, the A1-P1 and A3-P3 portions of the valve are located superoposterior and inferoanterior, respectively .
Emerging mitral valve transcatheter interventions require the positioning of the delivery catheter and device in a precise position relative to each leaflet and each segment. Recognizing the leaflet configuration in fluoroscopic chamber-view may facilitate this process.
A three-chamber view (extreme RAO/CAU view) provides maximum separation between the mural and aortic leaflets of the mitral valve. However, in this view both the aortic segments and the mural segments overlap one another. Two-chamber view (RAO/CRA view) allows physicians to achieve separation of the leaflet segment (1, 2, 3). In this view, mural and aortic leaflets overlap such that A1 overlaps P1, A2 overlaps P2, and A3 overlaps P3 (Fluoroscopic standardized views of the mitral and tricuspid valves. The one-chamber (short-axis) view (blue panels) show the en-face view of the mitral and tricuspid annulus seen by the ventricular side. The attachment of the anterior mitral leaflet (dashed purple lines) and posterior leaflet (dashed blue lines) are reported in each panel. The black arrows correspond to the scallops (A1, A2, A3) of the anterior mitral leaflet. The black arrows correspond to the scallops (P1, P2, P3) of the posterior mitral leaflet. The attachments of the anterior (black dotted line), posterior (green dotted line) and septal (orange dotted line) are reported in each panel. The continuous lines corresponding to the different chamber views. (A) The continue yellow line represents the plane of the 2-chamber view for the left side of the heart, which corresponds to the 3-chamber view for the right side of the heart (dashed red line); (B) The continue red line represents the plane of the 3-chamber view for the left side of the heart, which corresponds to the 2-chamber view for the right side of the heart (dashed yellow line); (C) The continue green line represents the plane of the 4-chamber view, which is identical for both the left and the right side of the heart. A = anterior; P = posterior; Ao = aortic valve; MV = mitral valve; TV = tricuspid valve.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-44.pptx"})' class="cursor-pointer">Figure 44).
Fluoroscopic standardized views of the mitral and tricuspid valves. The one-chamber (short-axis) view (blue panels) show the en-face view of the mitral and tricuspid annulus seen by the ventricular side. The attachment of the anterior mitral leaflet (dashed purple lines) and posterior leaflet (dashed blue lines) are reported in each panel. The black arrows correspond to the scallops (A1, A2, A3) of the anterior mitral leaflet. The black arrows correspond to the scallops (P1, P2, P3) of the posterior mitral leaflet. The attachments of the anterior (black dotted line), posterior (green dotted line) and septal (orange dotted line) are reported in each panel. The continuous lines corresponding to the different chamber views. (A) The continue yellow line represents the plane of the 2-chamber view for the left side of the heart, which corresponds to the 3-chamber view for the right side of the heart (dashed red line); (B) The continue red line represents the plane of the 3-chamber view for the left side of the heart, which corresponds to the 2-chamber view for the right side of the heart (dashed yellow line); (C) The continue green line represents the plane of the 4-chamber view, which is identical for both the left and the right side of the heart. A = anterior; P = posterior; Ao = aortic valve; MV = mitral valve; TV = tricuspid valve.
The mitral annulus has a maximum diameter (or intercommissural diameter), and a minimum diameter (or aortomural diameter). The sizing of the mitral annulus is important because the design of some transcatheter mitral valve replacement devices is not axially symmetric and must be positioned at a particular angle relative to the mitral commissure.
The intercommissural diameter can be obtained using a two-chamber view (mild RAO/CRA), which also provides maximal separation of papillary muscles. Conversely, the aortomural diameter of the mitral annulus can be appreciated in a three-chamber view (extreme RAO/CAU).
In the three-chamber view the aortic-mitral curtain, the area of fibrous continuity between the right and left trigones, is observed perpendicularly and clearly separated from the left atrium and the aortic root. This fluoroscopic projection could be of interest during transcatheter mitral valve bioprostheses implantation. Indeed, it can be helpful to evaluate the interaction between the prosthesis and the LVOT, particularly to assess the potential risk of LVOT obstruction or a deformation of the aortic-mitral curtain .
Papillary muscles lie in the posterior-half of the left ventricular cavity, and are described as inferoanterior and posterosuperior, according to attitudinal description. Their exact number, positioning, morphology, and thickness can vary considerably . Indeed, it is important to appreciate their fluoroscopic configuration, because they could be potential obstacles to the deployment of transcatheter devices especially if their structures protrude into the left ventricle, such as mitral valve prostheses or ventricular septal defect closure devices.
The tricuspid valve represents a main focus of interest among right-sided heart structures and target for transcatheter interventions. A transcatheter repair or replacement device may require a specific chamber view that provides the annulus in plane along with other structures of interest. The optimal projection curve of the tricuspid valve annulus spans across LAO/CRA, RAO/CRA and RAO/CAU with a characteristic steep slope in the RAO region. The region not spanned by the curve provides the en-face view of the structure (i.e. LAO/CAU). The plane of the tricuspid annulus can be appreciated in 2-, 3- or 4-chamber view (RAO/CAU, RAO/CRA, LAO/CRA, respectively). Potential useful chamber views and fluoroscopic angulations for the guidance of transcatheter procedures targeting the tricuspid valve are summarized in Table 2.
The 1-chamber (or short-axis) view (Multimodality imaging of the right side of the heart and tricuspid valve. Multimodality imaging of the left side of the heart, aortic and mitral valve. The optimal projection curves of the aortic and mitral annulus are plotted as a blue dotted line (aortic valve annulus) and green dotted line (mitral valve annulus). The region of fluoroscopic angulations corresponding to each of the chamber views is indicated by circles. The panels correspond to the two-chamber (yellow), three- chamber (red) and the four-chamber (green) views. Each panel presents the matching echocardiographic and MSCT images corresponding to the fluoroscopic view of interest (circles). LAO: left anterior oblique; MSCT: multislice computed tomography; RAO: right anterior oblique; TOE: transoesophageal echocardiography; TTE: transthoracic echocardiography.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-14.pptx"})' class="cursor-pointer">Figure 14 and Fluoroscopic right sided cardiac structures in A (one chamber), B (two chamber), C (three chamber) and D (four chamber) view. The main cardiac structures are highlighted with circles, namely: tricuspid valve (violet), free edge of the anterior (yellow), septal (white) and posterior (blue) tricuspid valve leaflets, superior papillary muscle (green dot), inferoposterior papillary muscle (violet dot), inferoanterior papillary muscle (red dot), pulmonary valve (blue), inferior vena cava (orange), superior vena cava (turquoise), coronary sinus (red), and interatrial septum (green).\u00a0<\/span><\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-15.pptx"})' class="cursor-pointer">Figure 15) is useful to navigate catheters towards the anterior, posterior or septal leaflet of the tricuspid valve. Given that the right coronary artery (RCA) runs along the tricuspid valve annulus, the 1-chamber view can provide useful information about the spatial relationship between the RCA and tricuspid annulus. This view (“en-face” view of the tricuspid annulus) is essential when performing transcatheter annuloplasty of the tricuspid annulus as it allows to appreciate the relationship between the anchors and the artery.
The 2-chamber view (Multimodality imaging of the right side of the heart and tricuspid valve. Multimodality imaging of the left side of the heart, aortic and mitral valve. The optimal projection curves of the aortic and mitral annulus are plotted as a blue dotted line (aortic valve annulus) and green dotted line (mitral valve annulus). The region of fluoroscopic angulations corresponding to each of the chamber views is indicated by circles. The panels correspond to the two-chamber (yellow), three- chamber (red) and the four-chamber (green) views. Each panel presents the matching echocardiographic and MSCT images corresponding to the fluoroscopic view of interest (circles). LAO: left anterior oblique; MSCT: multislice computed tomography; RAO: right anterior oblique; TOE: transoesophageal echocardiography; TTE: transthoracic echocardiography.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-14.pptx"})' class="cursor-pointer">Figure 14 and Fluoroscopic right sided cardiac structures in A (one chamber), B (two chamber), C (three chamber) and D (four chamber) view. The main cardiac structures are highlighted with circles, namely: tricuspid valve (violet), free edge of the anterior (yellow), septal (white) and posterior (blue) tricuspid valve leaflets, superior papillary muscle (green dot), inferoposterior papillary muscle (violet dot), inferoanterior papillary muscle (red dot), pulmonary valve (blue), inferior vena cava (orange), superior vena cava (turquoise), coronary sinus (red), and interatrial septum (green).\u00a0<\/span><\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-15.pptx"})' class="cursor-pointer">Figure 15) of the right heart provides maximum separation between papillary muscles and it is potentially useful to avoid entrapment in the subvalvular structures and permits to safely achieve the positioning of specific devices in the right ventricular apex. It also provides the coronary sinus and tricuspid valve both in plane thereby mitigating parallax between these 2 structures and can facilitate cannulation of the coronary sinus (vs. tricuspid annulus).
The 3-chamber view of the right heart (Multimodality imaging of the right side of the heart and tricuspid valve. Multimodality imaging of the left side of the heart, aortic and mitral valve. The optimal projection curves of the aortic and mitral annulus are plotted as a blue dotted line (aortic valve annulus) and green dotted line (mitral valve annulus). The region of fluoroscopic angulations corresponding to each of the chamber views is indicated by circles. The panels correspond to the two-chamber (yellow), three- chamber (red) and the four-chamber (green) views. Each panel presents the matching echocardiographic and MSCT images corresponding to the fluoroscopic view of interest (circles). LAO: left anterior oblique; MSCT: multislice computed tomography; RAO: right anterior oblique; TOE: transoesophageal echocardiography; TTE: transthoracic echocardiography.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-14.pptx"})' class="cursor-pointer">Figure 14 and Fluoroscopic right sided cardiac structures in A (one chamber), B (two chamber), C (three chamber) and D (four chamber) view. The main cardiac structures are highlighted with circles, namely: tricuspid valve (violet), free edge of the anterior (yellow), septal (white) and posterior (blue) tricuspid valve leaflets, superior papillary muscle (green dot), inferoposterior papillary muscle (violet dot), inferoanterior papillary muscle (red dot), pulmonary valve (blue), inferior vena cava (orange), superior vena cava (turquoise), coronary sinus (red), and interatrial septum (green).\u00a0<\/span><\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-15.pptx"})' class="cursor-pointer">Figure 15) provides a long-axis view of the right ventricle and is similar to the 3-chamber view of the left heart with respect to elongating the ventricular outflow tract and overlapping papillary muscles. In the 3-chamber view, the tricuspid and pulmonary valves can be found in plane; given that the RVOT is elongated, this view can be useful during transcatheter tricuspid or pulmonary valve replacement. Because this view separates the posterior and septal tricuspid valve leaflet, it can guide clip orientation during posterior-septal leaflet approximation. The 3-chamber view has the coronary sinus en-face, which should be discouraged during cannulation procedures of the coronary sinus.
The 4-chamber view of the right heart (Multimodality imaging of the right side of the heart and tricuspid valve. Multimodality imaging of the left side of the heart, aortic and mitral valve. The optimal projection curves of the aortic and mitral annulus are plotted as a blue dotted line (aortic valve annulus) and green dotted line (mitral valve annulus). The region of fluoroscopic angulations corresponding to each of the chamber views is indicated by circles. The panels correspond to the two-chamber (yellow), three- chamber (red) and the four-chamber (green) views. Each panel presents the matching echocardiographic and MSCT images corresponding to the fluoroscopic view of interest (circles). LAO: left anterior oblique; MSCT: multislice computed tomography; RAO: right anterior oblique; TOE: transoesophageal echocardiography; TTE: transthoracic echocardiography.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-14.pptx"})' class="cursor-pointer">Figure 14 and Fluoroscopic right sided cardiac structures in A (one chamber), B (two chamber), C (three chamber) and D (four chamber) view. The main cardiac structures are highlighted with circles, namely: tricuspid valve (violet), free edge of the anterior (yellow), septal (white) and posterior (blue) tricuspid valve leaflets, superior papillary muscle (green dot), inferoposterior papillary muscle (violet dot), inferoanterior papillary muscle (red dot), pulmonary valve (blue), inferior vena cava (orange), superior vena cava (turquoise), coronary sinus (red), and interatrial septum (green).\u00a0<\/span><\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-15.pptx"})' class="cursor-pointer">Figure 15) can be obtained with the AS and tricuspid valve annulus both in plane. The atrial and ventricular septum can be clearly visualized; this can be a useful view during ventricular septal defect closure or pacemaker positioning against the ventricular septum. The majority of tricuspid clip procedures aim to approximate the anterior and septal tricuspid valve leaflets. Because the 4-chamber view separates the anterior and septal tricuspid valve leaflets, it can complement echocardiography during clip orientation.
Invasive coronary angiography (ICA) has excellent resolution and remains the gold standard of coronary imaging since the late 1970s . Meanwhile, fluoroscopy holds several important drawbacks:
1- the inert dependency on contrast agent radiopacity for visualization of structures has accustomed operators to focus on contrast-enhanced vessels, while ignoring the underlying heart wall/structures.
2- fluoroscopy has historically been performed using a limited set of routine viewing angles as “one-size-fits-all” approach, which is frequently suboptimal in patients with anatomic variations or disease-specific remodeling.
3- the 2D nature of fluoroscopy often hampers estimation of vessel caliber and length due to parallax/foreshortening. In addition, vessels overlap frequently impedes optimal assessment of arteries/branches.
These pitfalls may result in misdiagnosis of the severity of coronary artery disease (CAD) or cause geographic miss during interventions leading to target vessel revascularization, especially in those cases of coronary ostial or bifurcation stenting. Pre-procedural coronary assessment by 3D tomography might help to overcome the limitations of fluoroscopy by providing crucial information regarding coronary anatomy and optimal strategy of PCI. In the current section we describe the fluoroscopic coronary anatomy in light of chamber views and discuss potential implications of 3D imaging in the planning of fluoroscopy-guided coronary interventions.
Fluoroscopic chamber views can be used as reference patterns for description of the coronary tree anatomy. Correct perception of the relation between angiographic coronary patterns and associated cardiac walls/structures might allow for better understanding of the applications of specific fluoroscopic angles during diagnostic and interventional procedures. Attitudinally, the coronary tree sprawls on an atrioventricular/short-axis, extending rightward and inferiorly, and an interventricular/long-axis, extending leftward and inferiorly (Cardiac short and long axes in a four-chamber view (LAO\/CRA) during coronary angiography. The coronary tree sprawls on an atrioventricular\/short-axis, extending rightward and inferiorly, and an interventricular\/long-axis, extending leftward and inferiorly (A). Left ventricle angiogram in a four-chamber view shows the anterolateral, apical and anteroseptal walls of the left ventricle (B). The RCA circumvents the tricuspid valve along the atrioventricular axis (C). The LAD artery runs leftward and inferiorly toward the apex along the interventricular cardiac axis (D).<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-45.pptx"})' class="cursor-pointer">Figure 45). An orthogonal projection of these two axes can be obtained by a cardiac four-chamber view across imaging modalities, including fluoroscopy (LAO/CRA). In this view, the left anterior descending (LAD) artery is seen elongated running within the anterior interventricular groove toward the apex supplying the anterior wall of the heart. Posterior descending artery is seen overlapped with LAD running within the posterior interventricular groove supplying the postero-inferior wall. Indeed, coronary dominance can be readily determined in this view. Diagonal branches arise laterally and supply the antero-lateral wall. Septal branches are also seen supplying the septal wall. The left circumflex and right coronary arteries circumvent the mitral and tricuspid annuli, respectively, within the atrioventricular groove which appear in plane. Obtuse marginal branches from the circumflex artery and acute marginal branches from the RCA run inferiorly and supply the postero-lateral and lateral walls of the left and right ventricle, respectively.
Cardiac short and long axes in a four-chamber view (LAO/CRA) during coronary angiography. The coronary tree sprawls on an atrioventricular/short-axis, extending rightward and inferiorly, and an interventricular/long-axis, extending leftward and inferiorly (A). Left ventricle angiogram in a four-chamber view shows the anterolateral, apical and anteroseptal walls of the left ventricle (B). The RCA circumvents the tricuspid valve along the atrioventricular axis (C). The LAD artery runs leftward and inferiorly toward the apex along the interventricular cardiac axis (D).
The cardiac atrioventricular/short axis can be projected in one chamber or “spider” view (LAO/CAU). In this view the left main coronary artery (LMCA) originating from the left coronary sinus appears elongated and its bifurcation into the LAD artery and circumflex arteries can be properly appreciated. The mitral and tricuspid annuli appear en-face circumvented by the left circumflex artery and RCA within the atrioventricular groove. Vessels with a course toward the apex, along the interventricular axis - the LAD artery, its diagonal branches and the obtuse marginals of the circumflex artery - appear with various degree of foreshortening (Coronary anatomy from a fluoroscopic one chamber view of the left heart (LAO\/CAU). In this view the RCA (purple) and circumflex (yellow) are seen elongated in its course along atrioventricular groove. The posterior descending artery is foreshortened. The LAD (red) is foreshortened within the interventricular groove.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-46.pptx"})' class="cursor-pointer">Figure 46).
Coronary anatomy from a fluoroscopic one chamber view of the left heart (LAO/CAU). In this view the RCA (purple) and circumflex (yellow) are seen elongated in its course along atrioventricular groove. The posterior descending artery is foreshortened. The LAD (red) is foreshortened within the interventricular groove.
A mirror image of the LAD/circumflex arteries pattern obtained in one chamber view can be obtained in an opposite projection (RAO/CRA) on a two-chamber view of the left heart (Coronary anatomy from a fluoroscopic two chamber view of the left heart (RAO\/CRA). In this view the LAD is seen fully elongated in its course along the anterior wall (red) and the circumflex artery is foreshortened within the atrioventricular groove (yellow-green). The mid-RCA (purple) can be also appreciated while the proximal and distal parts are foreshortened.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-47.pptx"})' class="cursor-pointer">Figure 47). In this view it is the LAD that is seen fully elongated in its course along the anterior wall while the circumflex artery is foreshortened within the atrioventricular groove. From this view a caudal rotation toward the three-chamber view will separate the aortic and mitral valve and elongate the course of the circumflex artery and its marginal branches. The three-chamber view of the left heart display the LAD along the anteroseptal wall, well separated from the circumflex artery which run an orthogonal course toward the inferolateral wall (Coronary anatomy from a fluoroscopic three chamber view (RAO\/CAU). On three-chamber view, the mitral and aortic valve are both in plane. Left system (A) - display the LAD artery (red) along the anteroseptal wall, well separated from the circumflex artery (yellow-green) which run an orthogonal course toward the inferolateral wall. Right system (B) - the mid RCA (purple) is fully elongated along the atrioventricular axis while the proximal and distal parts are foreshortened.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-48.pptx"})' class="cursor-pointer">Figure 48).
Coronary anatomy from a fluoroscopic two chamber view of the left heart (RAO/CRA). In this view the LAD is seen fully elongated in its course along the anterior wall (red) and the circumflex artery is foreshortened within the atrioventricular groove (yellow-green). The mid-RCA (purple) can be also appreciated while the proximal and distal parts are foreshortened.
Coronary anatomy from a fluoroscopic three chamber view (RAO/CAU). On three-chamber view, the mitral and aortic valve are both in plane. Left system (A) - display the LAD artery (red) along the anteroseptal wall, well separated from the circumflex artery (yellow-green) which run an orthogonal course toward the inferolateral wall. Right system (B) - the mid RCA (purple) is fully elongated along the atrioventricular axis while the proximal and distal parts are foreshortened.
Myocardial perfusion scan can be also interpreted as chamber views. In fact, the distribution of the radioactive tracer across the heart walls is represented in one chamber (anterior, posterior, septal and lateral walls), two chamber (anterior and inferior walls) and, four chamber (septal and lateral walls).
Optimal fluoroscopic projections during PCI should minimize parallax/foreshortening of the aorto-coronary ostia and coronary vessels in order to provide the operators with accurate information about the caliber and length of the evaluated vessel. In addition, vessel overlap should be minimized by “separating” the segment of interest from adjacent branches. Optimal viewing angle is often challenging to achieve, especially while assessing coronary ostia and bifurcations. Suboptimal viewing angles may lead to an increase in procedural time, contrast agent administration and radiation exposure from one hand and to non-favorable procedural results from the other.
Improvements in acquisition and reconstruction technology propelled the use of coronary computed tomography angiography (CCTA) as a first-line diagnostic tool for management of patients with suspected CAD. Less commonly recognized, is the concept of exploiting “au maximum” the 3D CTCA volume dataset to better inform the interventional cardiologist on “how to perform” the PCI. CCTA may allow for optimal selection of vascular access, fluoroscopic viewing angles, PCI strategy and adequate equipment, while preventing ICA-associated technical errors and potential sequelae (The multiple potential roles of CCTA in planning of coronary interventions. CCTA allow for optimal selection of vascular access, equipment selection, fluoroscopic viewing angles, PCI strategy, while reducing contrast agent volume, radiation exposure and PCI-associated technical errors and potential sequelae. CCTA: coronary computed tomography angiography.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-49.pptx"})' class="cursor-pointer">Figure 49). Importantly, CCTA has the potential to reduce patient contrast load, radiation exposure and procedure times, and has been demonstrated to be cost-effective when appropriately incorporated into clinical workflows. While further studies are in need to establish the role of CCTA as interventional tool, it is reasonable that in the near future CCTA will replace ICA not only in CAD diagnosis, but also in PCI guidance.
The multiple potential roles of CCTA in planning of coronary interventions. CCTA allow for optimal selection of vascular access, equipment selection, fluoroscopic viewing angles, PCI strategy, while reducing contrast agent volume, radiation exposure and PCI-associated technical errors and potential sequelae. CCTA: coronary computed tomography angiography.
Recommendations for the most appropriate fluoroscopic views for PCI are mostly empirical and lack an evidence-based approach . Apart from CAD severity, CCTA offers crucial 3D anatomical information that can potentially dictate optimal working angles for interventions. This information might also guide selection of adequate equipment for intervention (e.g. guiding catheter shape, guidewire type and number, balloon/stent size and length, need for atherectomy), as well as optimal PCI strategy based on lesion characteristics (e.g. culprit artery localization, 1 vs. 2 stent bifurcation stenting, chronic total occlusions). The contribution of CCTA might be of particular importance while intervening in ostia of coronary arteries and proximal bifurcations considering the higher risk of geographic miss on this type of coronary lesion due to poor visualization of the stent landing zone. Eventually, though yet to be determined, CTCA may potentially improve the clinical outcomes of coronary interventions.
Planning of optimal working angles for coronary interventions by CCTA is based on the same principles learned from planning of structural heart interventions (e.g. TAVI, left atrial appendage closure). First, two perpendicular cross-sections of the evaluated coronary segment should be identified. Then, optimal projection curve of each one of the identified planes is generated by automated software. Finally, the intersection point between the two S-curves should provide the operator with a viewing angle that will minimize parallax/foreshortening of the vessel (Analysis of optimal fluoroscopic viewing angles for ostial and proximal left main stenting. Ostium of the left main is identified in two orthogonal planes (A; turquoise closed spline). A centerline (green line) of the left main is created to identify the perpendicular plane of the proximal left main at 8 mm from the ostium (B). Optimal projection curves are then developed for the aortic annulus (yellow curve) and the ostial and proximal left main (turquoise and orange curves, respectively) (C). The fluoroscopic viewing angle obtained by the intersection between the aortic annulus and ostial left main optimal projection curves (D) mitigates parallax of the aortic root and allows a clear identification of the ostial left main. The fluoroscopic viewing angle obtained by the intersection between the ostial and proximal left main optimal projection curves (E) mitigates parallax of the proximal left main.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-50.pptx"})' class="cursor-pointer">Figure 50). For example, the coordinates of intersection between the optimal projection curves of the ostial LAD and the proximal LAD (~8mm distal to the ostium) should provide an optimal viewing angle for stenting of the ostial LAD. Likewise, for ostial LMCA stenting, the intersection between the optimal projection curves of the aortic annulus and of the ostial LMCA should provide an optimal viewing angle in which the aortic root is fully elongated and the LMCA appears in a perpendicular plane. Importantly, as previously mentioned the double S-curve between the left coronary ostium and aortic annulus isolates the left coronary cusp, while the double S-curve between the right coronary ostium and aortic annulus isolates the right coronary cusp. In other words, by isolating the left coronary cusp (i.e., 2 cusp non-right overlap view in LAO CRA) and right coronary cusp (i.e., 2 cusp non-left overlap view in steep LAO CRA), optimal viewing angles of the left main and right coronary ostia, respectively, can be obtained, thereby avoiding the need for double S-curve software programs.
Analysis of optimal fluoroscopic viewing angles for ostial and proximal left main stenting. Ostium of the left main is identified in two orthogonal planes (A; turquoise closed spline). A centerline (green line) of the left main is created to identify the perpendicular plane of the proximal left main at 8 mm from the ostium (B). Optimal projection curves are then developed for the aortic annulus (yellow curve) and the ostial and proximal left main (turquoise and orange curves, respectively) (C). The fluoroscopic viewing angle obtained by the intersection between the aortic annulus and ostial left main optimal projection curves (D) mitigates parallax of the aortic root and allows a clear identification of the ostial left main. The fluoroscopic viewing angle obtained by the intersection between the ostial and proximal left main optimal projection curves (E) mitigates parallax of the proximal left main.
For coronary bifurcation stenting, optimal angles can be generated by creating a 3-point closed spline involving (a) the proximal main branch, (b) the distal main branch and (c) the side branch and subsequently calculating the en-face fluoroscopic viewing angle of that spline (Analysis of optimal fluoroscopic viewing angles of bifurcating coronary arteries. A centerline is created in the LAD artery at least 5 mm proximally and distally from the diagonal branch take-off. Curved multiplanar reconstruction is used to create a center line and identify the bifurcation (inlet). The plane or en-face view of the bifurcation is created by placing 3 dots in the proximal main vessel, distal main vessel, and diagonal branch at 5 mm distance from the polygon of confluence. The en-face view of the plane provides the optimal fluoroscopic projection for analyzing bifurcation lesions.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-51.pptx"})' class="cursor-pointer">Figure 51). The en-face viewing angle of this plane provides optimal assessment of the bifurcation geometry. Optimal fluoroscopic projections of coronary ostia and bifurcations defined by CCTA. Shown are optimal viewing angles for PCI of the right and left coronary ostia, as well as coronary bifurcations based on a retrospective analysis of 100 consecutive patients who underwent CTCA for suspected CAD.<\/span><\/p>","mediaType":"image","mediaMimeType":"image\/jpeg","mediaPPT":"PCR_Textbook_Chapter-FLUOROSCOPIC-ANATOMY-FOR-THE-GUIDANCE-OF-TRANSCATHETER-STRUCTURAL-AND-CORONARY-INTERVENTION--OLD-_FIGURE-52.pptx"})' class="cursor-pointer">Figure 52 describes the average optimal viewing angles for stenting of coronary ostia (LMCA and RCA) and, bifurcations based on a retrospective analysis of 100 consecutive patients who underwent CTCA for suspected CAD .
Analysis of optimal fluoroscopic viewing angles of bifurcating coronary arteries. A centerline is created in the LAD artery at least 5 mm proximally and distally from the diagonal branch take-off. Curved multiplanar reconstruction is used to create a center line and identify the bifurcation (inlet). The plane or en-face view of the bifurcation is created by placing 3 dots in the proximal main vessel, distal main vessel, and diagonal branch at 5 mm distance from the polygon of confluence. The en-face view of the plane provides the optimal fluoroscopic projection for analyzing bifurcation lesions.
Optimal fluoroscopic projections of coronary ostia and bifurcations defined by CCTA. Shown are optimal viewing angles for PCI of the right and left coronary ostia, as well as coronary bifurcations based on a retrospective analysis of 100 consecutive patients who underwent CTCA for suspected CAD.
As the frequency of use of diagnostic CTCA increases in the near future, it has the potential to provide additional information for planning and guiding PCI procedures based on 3D tomographic dataset.
Historically, knowledge about fluoroscopic anatomy was acquired through anecdotal experience. Sub optimal fluoroscopic viewing angles are often underappreciated and can lead to significant foreshortening and parallax of cardiac structures with adverse effects on the evaluation and/or percutaneous intervention. Furthermore, classic teaching in interventional cardiology has been based on pattern recognition. With the introduction of multislice computed tomography for structural heart interventions, the idea of patient specific viewing angles has gained widespread acceptance. The current chapter provides a foundational approach to mastering fluoroscopic anatomy for both transcatheter structural and coronary interventions. This approach relies on the concepts of chamber views, that can be obtained in various fluoroscopic quadrants, and optimal projection curves that allow us to understand the en-face or planar view of a given structure. Combining fluoroscopic chamber views and optimal projection curves, we can better understand the location and relative position of cardiac structures. While we progress towards a mastering of fluoroscopic anatomy, we will inevitably eliminate the need to base our teaching solely on pattern recognition. Behind each catheter injection, lies a chamber view.
Horacio Medina de Chazal, Ali Zgheib, Angelo Quagliana, Michael Chetrit, Jean Buithieu, Giuseppe Martucci, Marco Spaziano, Ali Abualsaud, Ole de Baker, Laurence Campens, Pascal Theriault-Lauzier, Jere...
Updated on November 17, 2023
Nicola Buzzatti, Jean-Michel Juliard, Fabien Praz, Alec Vahanian, Azeem Latib, Eric Brochet, Phalla Ou, Dominique Himbert, Mirjam Wild, Domenico Angellotti
Updated on May 14, 2022
Gregory Ducrocq, Thomas R.D. Shaw, Habib Gamra, Peter C. Block, Neil R. Grubb, Carlos E. Ruiz, Alec Vahanian
Updated on November 22, 2022
Mirjam Wild, Maurizio Taramasso, Alison Duncan, Giulio Russo, Dominique Himbert, Francesco Maisano, Nicolo Piazza, Fabien Praz
Updated on November 21, 2021